The carrier fringes method has been proposed in digital photoelasticity in combination with techniques such as Fourier transform and phase shifting method, without considering the influence of the isoclinics on the isochromatic patterns analysis. Unlike other optical methods as moiré and holographic interferometry, in photoelasticity the light intensity emerging from a circular polariscope is related to both the isochromatic retardation and the isoclinic parameter. As it is shown by the theoretical analysis, owing to the misalignment between the principal stresses in the model and in the carrier, the computed retardation is affected by an error which is the same for all photoelastic methods based on the use of carrier fringes. Consequently, the photoelastic analysis carried out by methods that use carrier fringes cannot be applied as a full-field technique. In detail, numerical simulations show that the retardation error is comparable (less than 0.05 fringe orders) with that of other photoelastic methods provided that the misalignment between the principal stresses in the model and in the carrier is less than 30°. On the contrary, in the model zones where the misalignment is higher than 30°, the retardation measurement can be affected by non negligible errors (up to 0.25 fringe orders).
AJOVALASIT, A., PITARRESI, G., ZUCCARELLO, B. (2007). Elaborazione delle immagini con il metodo della trasformata di Fourier: il caso della fotoelasticità.. In International joined Conference XVI ADM - XIX INGEGRAF. (pp.---) [10.1016/j.optlaseng.2006.08.008].
Elaborazione delle immagini con il metodo della trasformata di Fourier: il caso della fotoelasticità.
AJOVALASIT, Augusto;PITARRESI, Giuseppe;ZUCCARELLO, Bernardo
2007-01-01
Abstract
The carrier fringes method has been proposed in digital photoelasticity in combination with techniques such as Fourier transform and phase shifting method, without considering the influence of the isoclinics on the isochromatic patterns analysis. Unlike other optical methods as moiré and holographic interferometry, in photoelasticity the light intensity emerging from a circular polariscope is related to both the isochromatic retardation and the isoclinic parameter. As it is shown by the theoretical analysis, owing to the misalignment between the principal stresses in the model and in the carrier, the computed retardation is affected by an error which is the same for all photoelastic methods based on the use of carrier fringes. Consequently, the photoelastic analysis carried out by methods that use carrier fringes cannot be applied as a full-field technique. In detail, numerical simulations show that the retardation error is comparable (less than 0.05 fringe orders) with that of other photoelastic methods provided that the misalignment between the principal stresses in the model and in the carrier is less than 30°. On the contrary, in the model zones where the misalignment is higher than 30°, the retardation measurement can be affected by non negligible errors (up to 0.25 fringe orders).I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.