Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), parameters of spectral estimator should be considered. In this study the surrogate data technique was introduced to define the level of significance of CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parameters of the adopted coherence estimator and on the record length, demonstrating the applicability of the method for all types of spectral estimator. This should favor its introduction for assessing the reliability of transfer function estimates in cardiovascular variability analysis.

Faes, L., Nollo, G., Antolini, R. (2001). Investigating the level of significance of the coherence function in cardiovascular variability analysis. In Computers in Cardiology (pp.481-484).

Investigating the level of significance of the coherence function in cardiovascular variability analysis

Faes, L.;
2001-01-01

Abstract

Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), parameters of spectral estimator should be considered. In this study the surrogate data technique was introduced to define the level of significance of CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parameters of the adopted coherence estimator and on the record length, demonstrating the applicability of the method for all types of spectral estimator. This should favor its introduction for assessing the reliability of transfer function estimates in cardiovascular variability analysis.
Settore ING-INF/06 - Bioingegneria Elettronica E Informatica
2001
Computer in Cardiology 2001
Rotterdam, nld
2001
2001
4
Faes, L., Nollo, G., Antolini, R. (2001). Investigating the level of significance of the coherence function in cardiovascular variability analysis. In Computers in Cardiology (pp.481-484).
Proceedings (atti dei congressi)
Faes, L.*; Nollo, G.; Antolini, R.
File in questo prodotto:
File Dimensione Formato  
A04-CiC2001-faes.pdf

Solo gestori archvio

Dimensione 281.85 kB
Formato Adobe PDF
281.85 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/278838
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact