The phase spectra obtained by the classical closed loop autoregressive model (2AR) and by an open loop autoregressive model (ARXAR) were compared to shed light on the need of introducing causality in the assessment of the delay between RR and arterial pressure oscillations. The reliability of the two approaches was tested in simulation and real data setting. In simulation, the coupling strength of a bivariate closed loop process was adjusted to obtain a range of working conditions from open to closed loop. In open loop condition, 2AR and ARXAR phases were comparable and in agreement with the imposed delay. In closed loop condition, ARXAR model returned the imposed delays, while 2AR showed an intermediate value of delay. Real data were chosen to represent comparable physiological condition. The use of cross spectrum for calculating the delay from arterial peressure to RR oscillations seems adequate only in particular condition of open-loop relationship as it happens during head up tilt in young healthy subjects.

Nollo, G., Widesott, L., Faes, L., Porta, A., Antolini, R. (2002). Need of causal analysis for assessing phase relationships in closed loop interacting cardiovascular variability series. In Computers in Cardiology (pp.61-64).

Need of causal analysis for assessing phase relationships in closed loop interacting cardiovascular variability series

Faes, L.;
2002-01-01

Abstract

The phase spectra obtained by the classical closed loop autoregressive model (2AR) and by an open loop autoregressive model (ARXAR) were compared to shed light on the need of introducing causality in the assessment of the delay between RR and arterial pressure oscillations. The reliability of the two approaches was tested in simulation and real data setting. In simulation, the coupling strength of a bivariate closed loop process was adjusted to obtain a range of working conditions from open to closed loop. In open loop condition, 2AR and ARXAR phases were comparable and in agreement with the imposed delay. In closed loop condition, ARXAR model returned the imposed delays, while 2AR showed an intermediate value of delay. Real data were chosen to represent comparable physiological condition. The use of cross spectrum for calculating the delay from arterial peressure to RR oscillations seems adequate only in particular condition of open-loop relationship as it happens during head up tilt in young healthy subjects.
Settore ING-INF/06 - Bioingegneria Elettronica E Informatica
2002
Computers in Cardiology 2002
Memphis, TN, usa
2002
2002
4
Nollo, G., Widesott, L., Faes, L., Porta, A., Antolini, R. (2002). Need of causal analysis for assessing phase relationships in closed loop interacting cardiovascular variability series. In Computers in Cardiology (pp.61-64).
Proceedings (atti dei congressi)
Nollo, Giandomenico; Widesott, L.; Faes, L.; Porta, A.; Antolini, R.
File in questo prodotto:
File Dimensione Formato  
A08-CiC2002-nollo.pdf

Solo gestori archvio

Dimensione 387.72 kB
Formato Adobe PDF
387.72 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/278832
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact