The measurement of the activation time is crucial to allow the correct automatic analysis and classification of intracardiac electrograms recorded in the human atria during atrial fibrillation (AF). This study proposes a method which accounts for the morphology of bipolar signals. After ventricular artifact removal and activation wave recognition, the fiducial point of the activation wave was set at its local barycentre (LB). The method was tested on a set of 30 AF bipolar recordings of increasing complexity class; its performance was compared with that of the traditional methods of maximum peak (MP) or maximum slope (MS) estimation, taking the manual measurements performed by an expert cardiologist as a reference. While for signals with low complexity the agreement with manual analysis was high for all automatic methods, in presence of disorganized AF characterized by complex morphology LB estimation resulted more reliable than MP or MS calculation.
Sandrini, L., Faes, L., Ravelli, F., Antolini, R., Nollo, G. (2002). Morphology-based measurement of activation time in human atrial fibrillation. In Computers in Cardiology (pp.593-596).
Morphology-based measurement of activation time in human atrial fibrillation
Faes, Luca;
2002-01-01
Abstract
The measurement of the activation time is crucial to allow the correct automatic analysis and classification of intracardiac electrograms recorded in the human atria during atrial fibrillation (AF). This study proposes a method which accounts for the morphology of bipolar signals. After ventricular artifact removal and activation wave recognition, the fiducial point of the activation wave was set at its local barycentre (LB). The method was tested on a set of 30 AF bipolar recordings of increasing complexity class; its performance was compared with that of the traditional methods of maximum peak (MP) or maximum slope (MS) estimation, taking the manual measurements performed by an expert cardiologist as a reference. While for signals with low complexity the agreement with manual analysis was high for all automatic methods, in presence of disorganized AF characterized by complex morphology LB estimation resulted more reliable than MP or MS calculation.File | Dimensione | Formato | |
---|---|---|---|
A07-CiC2002-sandrini.pdf
Solo gestori archvio
Dimensione
440.48 kB
Formato
Adobe PDF
|
440.48 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.