We introduce focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics with a balloon payload concept called, B-MINE. It is designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the velocity distribution of the 44Ti emitting region. BMINE has a thin plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3F sensitivity in 106 s of 6 × 10-8 ph cm-2 s-1 at 68 keV. During the course of a long duration balloon flight, B-MINE could carry out a detailed study of the 44Ti emission line centroids and width in CAS A. Details of the spectrometer and simulated results are presented.
SILVER E, SCHNOPPER H W, JONES C, FORMAN W, ROMAINE S, MADDEN N, et al. (2005). High Energy, High Resolution X-Ray Spectroscopy: Microcalorimeters For Nuclear Line Astrophysics. In AIP Conf. Proc. (pp.391-399) [10.1063/1.1960959].
High Energy, High Resolution X-Ray Spectroscopy: Microcalorimeters For Nuclear Line Astrophysics
BARBERA, Marco;
2005-01-01
Abstract
We introduce focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics with a balloon payload concept called, B-MINE. It is designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the velocity distribution of the 44Ti emitting region. BMINE has a thin plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3F sensitivity in 106 s of 6 × 10-8 ph cm-2 s-1 at 68 keV. During the course of a long duration balloon flight, B-MINE could carry out a detailed study of the 44Ti emission line centroids and width in CAS A. Details of the spectrometer and simulated results are presented.File | Dimensione | Formato | |
---|---|---|---|
xray-spec+scitation.pdf
Solo gestori archvio
Dimensione
460.31 kB
Formato
Adobe PDF
|
460.31 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.