We are conducting a measurement program on back-up filters of the XMM-Newton EPIC camera aimed at monitoring possible aging effects during the mission lifetime. One thin and one medium EPIC back-up filters have been stored since 1997 in an environment similar to that one of the flight filters (dry nitrogen box before launch, high vacuum after launch). The transmission of the two filters has been measured periodically in the 1900-10000 Å wavelength range where effects of aging would be clearly evident. The preliminary results, after 5 years of monitoring, show that a slight aging effect has occurred on both filters which, however, has no significant impact onto the EPIC calibration for the correct analysis of the X-ray astrophysical observations.

Barbera, M., Collura, A., Artale, M., Varisco, S., Peres, G., Sciortino, S., et al. (2002). Monitoring the stability of thin and medium back-up filters of the Newton-XMM EPIC camera. In Proceedings of SPIE - The International Society for Optical Engineering (pp.264-269) [10.1117/12.461592].

Monitoring the stability of thin and medium back-up filters of the Newton-XMM EPIC camera

BARBERA, Marco;PERES, Giovanni;SERIO, Salvatore;
2002-01-01

Abstract

We are conducting a measurement program on back-up filters of the XMM-Newton EPIC camera aimed at monitoring possible aging effects during the mission lifetime. One thin and one medium EPIC back-up filters have been stored since 1997 in an environment similar to that one of the flight filters (dry nitrogen box before launch, high vacuum after launch). The transmission of the two filters has been measured periodically in the 1900-10000 Å wavelength range where effects of aging would be clearly evident. The preliminary results, after 5 years of monitoring, show that a slight aging effect has occurred on both filters which, however, has no significant impact onto the EPIC calibration for the correct analysis of the X-ray astrophysical observations.
Settore FIS/05 - Astronomia E Astrofisica
X-ray and Gamma-Ray telescopes and Instruments for Astronomy
Waikoloa, HI, usa
2002
2002
6
Barbera, M., Collura, A., Artale, M., Varisco, S., Peres, G., Sciortino, S., et al. (2002). Monitoring the stability of thin and medium back-up filters of the Newton-XMM EPIC camera. In Proceedings of SPIE - The International Society for Optical Engineering (pp.264-269) [10.1117/12.461592].
Proceedings (atti dei congressi)
Barbera, M.; Collura, A.; Artale, M.; Varisco, S.; Peres, G.; Sciortino, S.; Serio, S.; Villa, G.
File in questo prodotto:
File Dimensione Formato  
264_1.pdf

Solo gestori archvio

Dimensione 295.73 kB
Formato Adobe PDF
295.73 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/214882
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact