Inside urban areas the earth electrodes of the MV/lv substations are often electrically connected together so as to form a single extended earthing system. The advantages of the realization of an extended earthing system are the reduction of the current that each substation earth electrode injects in the soil during the fault and a better uniformity of the voltages to earth inside the urban area. In previous works, models for the study of extended earthing systems have been proposed. These models were valid for the case of single-line-to earth fault in isolated neutral MV networks. In this paper, the extended earthing system is analyzed in the case of a resonant earthed neutral MV network. The mathematical model used for the analysis and an application example are shown and a comparison with the case of isolated neutral system is done.

CAMPOCCIA A, ZIZZO G (2005). A study of the behaviour of earth electrodes connected together in resonant earthed neutral systems. In Safety and Security Engineering - WIT Transactions on The Built Environment (pp.93-102). ASHURT LODGE, ASHURT : Wessex Institute of Technology.

A study of the behaviour of earth electrodes connected together in resonant earthed neutral systems

CAMPOCCIA, Angelo;ZIZZO, Gaetano
2005-01-01

Abstract

Inside urban areas the earth electrodes of the MV/lv substations are often electrically connected together so as to form a single extended earthing system. The advantages of the realization of an extended earthing system are the reduction of the current that each substation earth electrode injects in the soil during the fault and a better uniformity of the voltages to earth inside the urban area. In previous works, models for the study of extended earthing systems have been proposed. These models were valid for the case of single-line-to earth fault in isolated neutral MV networks. In this paper, the extended earthing system is analyzed in the case of a resonant earthed neutral MV network. The mathematical model used for the analysis and an application example are shown and a comparison with the case of isolated neutral system is done.
International Conference on Safety and Security Engineering
Roma
13-15 Jun, 2005
1
2005
10
CAMPOCCIA A, ZIZZO G (2005). A study of the behaviour of earth electrodes connected together in resonant earthed neutral systems. In Safety and Security Engineering - WIT Transactions on The Built Environment (pp.93-102). ASHURT LODGE, ASHURT : Wessex Institute of Technology.
Proceedings (atti dei congressi)
CAMPOCCIA A; ZIZZO G
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/21188
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact