The two-bus equivalent model is commonly used for voltage stability studies in both distribution and transmission systems. The paper presents a simple method to evaluate, for each bus, the parameters which define the equivalent circuit of a radial distribution network. In particular, a straightforward way for determining the Thévenin equivalent impedance behind a load node is proposed, which allows to better identify the maximum loading point beyond which the voltage collapse takes place in the network. Simulation results show that the proposed method is significantly more accurate than other existing methods on evaluating the critical power at a particular node (i.e. the weak node of the network) starting from any operating point.

AUGUGLIARO, A., DUSONCHET, L., FAVUZZA, S., MANGIONE, S. (2005). An improved method for determining voltage collapse proximity of radial distribution networks. In Proceedings of the 5th WSEAS International Conference on Power Systems and Electromagnetic Compatibility (PSE’05) (pp.78-84).

An improved method for determining voltage collapse proximity of radial distribution networks

AUGUGLIARO, Antonino;DUSONCHET, Luigi;FAVUZZA, Salvatore;MANGIONE, Stefano
2005-01-01

Abstract

The two-bus equivalent model is commonly used for voltage stability studies in both distribution and transmission systems. The paper presents a simple method to evaluate, for each bus, the parameters which define the equivalent circuit of a radial distribution network. In particular, a straightforward way for determining the Thévenin equivalent impedance behind a load node is proposed, which allows to better identify the maximum loading point beyond which the voltage collapse takes place in the network. Simulation results show that the proposed method is significantly more accurate than other existing methods on evaluating the critical power at a particular node (i.e. the weak node of the network) starting from any operating point.
Settore ING-IND/33 - Sistemi Elettrici Per L'Energia
ago-2005
5th WSEAS International Conference on Power Systems and Electromagnetic Compatibility (PSE'05)
Corfu, Greece
August 23-25, 2005
5th
2005
7
A stampa
AUGUGLIARO, A., DUSONCHET, L., FAVUZZA, S., MANGIONE, S. (2005). An improved method for determining voltage collapse proximity of radial distribution networks. In Proceedings of the 5th WSEAS International Conference on Power Systems and Electromagnetic Compatibility (PSE’05) (pp.78-84).
Proceedings (atti dei congressi)
AUGUGLIARO, A; DUSONCHET, L; FAVUZZA, S; MANGIONE, S
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/20594
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact