The achievement and the maintenance of dental implant stability are prerequisites for the long-term success of the osseointegration process. Since implant stability occurs at different stages, it is clinically required to monitor an implant over time, i.e. between the surgery and the placement of the artificial tooth. In this framework, non-invasive tests able to assess the degree of osseointegration are necessary. In this paper, the electromechanical impedance (EMI) method is proposed to monitor the stability of dental implants. A 3D finite element model of a piezoceramic transducer (PZT) bonded to a dental implant placed into the bone was created, considering the presence of a bone- implant interface subjected to Young’s modulus change. The numerical model was validated experimentally by testing bovine bone samples. The EMI response of a PZT, bonded to the abutment screwed to implants inserted to the bone, was measured. To simulate the osseointegration process a pulp canal sealer was used to secure the implant to the bone. It was found that the PZT’s admittance is sensitive to the stiffness variation of the bone-implant interface. The results are promising because they show the potential of EMI method to (i) evaluate the material properties around dental implant, and (ii) promote a novel non-invasive monitoring of dental implant surgical procedure.

La Malfa Ribolla, E., Rizzo, P., Gulizzi, V. (2014). On the use of EMI for the assessment of dental implant stability. In Proceedings of SPIE - The International Society for Optical Engineering.

On the use of EMI for the assessment of dental implant stability

La Malfa Ribolla, Emma;RIZZO, PIERVINCENZO;Gulizzi, Vincenzo
2014-01-01

Abstract

The achievement and the maintenance of dental implant stability are prerequisites for the long-term success of the osseointegration process. Since implant stability occurs at different stages, it is clinically required to monitor an implant over time, i.e. between the surgery and the placement of the artificial tooth. In this framework, non-invasive tests able to assess the degree of osseointegration are necessary. In this paper, the electromechanical impedance (EMI) method is proposed to monitor the stability of dental implants. A 3D finite element model of a piezoceramic transducer (PZT) bonded to a dental implant placed into the bone was created, considering the presence of a bone- implant interface subjected to Young’s modulus change. The numerical model was validated experimentally by testing bovine bone samples. The EMI response of a PZT, bonded to the abutment screwed to implants inserted to the bone, was measured. To simulate the osseointegration process a pulp canal sealer was used to secure the implant to the bone. It was found that the PZT’s admittance is sensitive to the stiffness variation of the bone-implant interface. The results are promising because they show the potential of EMI method to (i) evaluate the material properties around dental implant, and (ii) promote a novel non-invasive monitoring of dental implant surgical procedure.
10-mar-2014
SPIE
San Diego
10 March 2014 through 13 March 2014
2014
10
La Malfa Ribolla, E., Rizzo, P., Gulizzi, V. (2014). On the use of EMI for the assessment of dental implant stability. In Proceedings of SPIE - The International Society for Optical Engineering.
Proceedings (atti dei congressi)
La Malfa Ribolla, E; Rizzo, P; Gulizzi, V.
File in questo prodotto:
File Dimensione Formato  
EMI_SPIE2014.pdf

accesso aperto

Descrizione: Article
Dimensione 2.22 MB
Formato Adobe PDF
2.22 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/101280
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact