This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers

BARBARO P V, CATALIOTTI A, COSENTINO V, NUCCIO S (2007). Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers. In 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007 (pp.1-6) [10.1109/IMTC.2007.378983].

Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers

BARBARO, Pietro Vincenzo;CATALIOTTI, Antonio;COSENTINO, Valentina;NUCCIO, Salvatore
2007-01-01

Abstract

This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers
Settore ING-INF/07 - Misure Elettriche E Elettroniche
24th IEEE. Instrumentation and Measurement Technology Conference, IMTC 2007
Warsaw, Poland
May 1-3 2007
2007
6
https://ieeexplore.ieee.org/document/4258327
Atti su CD e su Sito web IEEE
BARBARO P V, CATALIOTTI A, COSENTINO V, NUCCIO S (2007). Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers. In 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007 (pp.1-6) [10.1109/IMTC.2007.378983].
Proceedings (atti dei congressi)
BARBARO P V; CATALIOTTI A; COSENTINO V; NUCCIO S
File in questo prodotto:
File Dimensione Formato  
Detection of Disturbing.pdf

Solo gestori archvio

Dimensione 2.66 MB
Formato Adobe PDF
2.66 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/9491
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 0
social impact