The development of type B aortic dissection (AoD) is caused by altered haemodynamic forces exerted on false and true lumina of dissected aorta. This work aims to study haemodynamic and morphological proprieties, which influence the progression or stability of type B AoD. Computational fluid-dynamic analyses were performed on three patients with type B AoD, whose two presented an aneurysm evolution and one presented no further complication connected with dissection. Blood flow features showed that the true lumen flow was laminar and uniform while false lumen flow lost the laminar characteristic with consequent vorticity formation. The entry point zone proximal to the aortic arch showed both high blood velocity and pressure connected with peaks of maximum WSS value. A negative pressure gradient between the false lumen entry and re-entry points was observed. This promotes the blood to flow towards the abdominal aorta reducing the risk of retrograde flow during systole. We concluded that fluid dynamics study of patients with type B AoD is a valid tool to identify the risk of aortic dissection progression as well as the formation of aortic dissection connected pathology.

Rinaudo, A., D'Ancona, G., Pasta, S. (2013). STUDIO NUMERICO DELL'EMODINAMICA IN PAZIENTI CON DISSECAZIONE AORTICA DI TIPO B. In Proceedings of 42° Convegno Nazionale AIAS 2013 Salerno 11-14 settembre.

STUDIO NUMERICO DELL'EMODINAMICA IN PAZIENTI CON DISSECAZIONE AORTICA DI TIPO B

RINAUDO, Antonino;Pasta, S.
2013-01-01

Abstract

The development of type B aortic dissection (AoD) is caused by altered haemodynamic forces exerted on false and true lumina of dissected aorta. This work aims to study haemodynamic and morphological proprieties, which influence the progression or stability of type B AoD. Computational fluid-dynamic analyses were performed on three patients with type B AoD, whose two presented an aneurysm evolution and one presented no further complication connected with dissection. Blood flow features showed that the true lumen flow was laminar and uniform while false lumen flow lost the laminar characteristic with consequent vorticity formation. The entry point zone proximal to the aortic arch showed both high blood velocity and pressure connected with peaks of maximum WSS value. A negative pressure gradient between the false lumen entry and re-entry points was observed. This promotes the blood to flow towards the abdominal aorta reducing the risk of retrograde flow during systole. We concluded that fluid dynamics study of patients with type B AoD is a valid tool to identify the risk of aortic dissection progression as well as the formation of aortic dissection connected pathology.
Settore ING-IND/14 - Progettazione Meccanica E Costruzione Di Macchine
set-2013
AIAS – ASSOCIAZIONE ITALIANA PER L’ANALISI DELLE SOLLECITAZIONI 42° CONVEGNO NAZIONALE
Salerno
11-14 Settembre 2013
2013
9
Rinaudo, A., D'Ancona, G., Pasta, S. (2013). STUDIO NUMERICO DELL'EMODINAMICA IN PAZIENTI CON DISSECAZIONE AORTICA DI TIPO B. In Proceedings of 42° Convegno Nazionale AIAS 2013 Salerno 11-14 settembre.
Proceedings (atti dei congressi)
Rinaudo, A; D'Ancona, G; Pasta, S
File in questo prodotto:
File Dimensione Formato  
202_AIAS_2013_Rinaudo_D'Ancona_Pasta.pdf

accesso aperto

Dimensione 2.18 MB
Formato Adobe PDF
2.18 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/94245
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact