Introduction In the last decades, the use of near-infrared room-temperature diode lasers for gas sensing has grown significantly. The use of these devices, for instance in combination with optical fibers, is particularly convenient for volcanic monitoring applications [1,2]. Here, we report on the first results of the application of an open-path infrared tunable laser-based at Campi Flegrei (Southern Italy). Such Diode-laser-based measurements were performed, during two field campaigns (october 2012, and january 2013), in the attempt to obtain novel information on the current degassing unrest of Solfatara and Pisciarelli fumarolic fields. Results and Discussion At each site, we used an ad-hoc designed measurement geometry, using a TDLS (a Gas Finder unit) and several differently positioned retroreflectors (mirrors), to scan the fumaroles’ plume from different angles and distances. From post-processing of the data (acquired at 1 hz), we derived tomographic maps of CO2 concentrations in the plume and, by integration and combination with plume transport speed (from video cameras), we inferred the CO2 flux directly. The so-calculated fluxes, the first ever obtained at Campi Flegrei, average of 500 tons/day, and support a significant contribution of fumaroles to the total CO2 budget. The cumulative (fumarole [this study] +soil [3]) CO2 output from Campi Flegrei is finally evaluated at 1600 tons/day. [1] Gianfrani L. et al. (2000). Appl. Phys. B-Rapid Common. 70, 467-470. [2] Richter D. et al (2002), Optics and Lasers in Engineering, Volume 37, Issues 2–3, Pages 171-186. [3] Chiodini G. et al. (2010), Journal of Geophysical Research, Volume 115, B03205, doi:10.1029/2008JB006258.
PEDONE, M., AIUPPA, A., GIUDICE, G., GRASSA, F., CHIODINI G (2013). VOLCANIC CO2 FLUX MEASUREMENTS BY TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY. In GOLDSCHMIDT2013 CONFERENCE ABSTRACTS.
VOLCANIC CO2 FLUX MEASUREMENTS BY TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY
PEDONE, Maria;AIUPPA, Alessandro;
2013-01-01
Abstract
Introduction In the last decades, the use of near-infrared room-temperature diode lasers for gas sensing has grown significantly. The use of these devices, for instance in combination with optical fibers, is particularly convenient for volcanic monitoring applications [1,2]. Here, we report on the first results of the application of an open-path infrared tunable laser-based at Campi Flegrei (Southern Italy). Such Diode-laser-based measurements were performed, during two field campaigns (october 2012, and january 2013), in the attempt to obtain novel information on the current degassing unrest of Solfatara and Pisciarelli fumarolic fields. Results and Discussion At each site, we used an ad-hoc designed measurement geometry, using a TDLS (a Gas Finder unit) and several differently positioned retroreflectors (mirrors), to scan the fumaroles’ plume from different angles and distances. From post-processing of the data (acquired at 1 hz), we derived tomographic maps of CO2 concentrations in the plume and, by integration and combination with plume transport speed (from video cameras), we inferred the CO2 flux directly. The so-calculated fluxes, the first ever obtained at Campi Flegrei, average of 500 tons/day, and support a significant contribution of fumaroles to the total CO2 budget. The cumulative (fumarole [this study] +soil [3]) CO2 output from Campi Flegrei is finally evaluated at 1600 tons/day. [1] Gianfrani L. et al. (2000). Appl. Phys. B-Rapid Common. 70, 467-470. [2] Richter D. et al (2002), Optics and Lasers in Engineering, Volume 37, Issues 2–3, Pages 171-186. [3] Chiodini G. et al. (2010), Journal of Geophysical Research, Volume 115, B03205, doi:10.1029/2008JB006258.File | Dimensione | Formato | |
---|---|---|---|
1944_abstract Goldschmidt2013FI_Pedone.pdf
accesso aperto
Descrizione: ABSTRACT
Dimensione
126.95 kB
Formato
Adobe PDF
|
126.95 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.