This paper presents the results of an experimental analysis comparing the performance of a vapour compression refrigerating unit operating with R22, and its performance in comparison to a new HFC fluid, substituting the former according to Regulation No 2037/2000.In particular, the plant working efficiency was first tested with R22 and then with three new HFC fluids: R417A, R422A and R422D. The investigation verified that despite the case of substitution and the advantage of being able to continue to use mineral oil as a lubricant in the compressor, the performance with the new tested fluids did not result as efficient as when using R22.

La Rocca, V., Panno, G. (2011). Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants. APPLIED ENERGY, Volume 88, Issue 8, August 2011(Issue 8), 2809-2815 [10.1016/j.apenergy.2011.01.051Document].

Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants

LA ROCCA, Vincenzo;PANNO, Giuseppe
2011-01-01

Abstract

This paper presents the results of an experimental analysis comparing the performance of a vapour compression refrigerating unit operating with R22, and its performance in comparison to a new HFC fluid, substituting the former according to Regulation No 2037/2000.In particular, the plant working efficiency was first tested with R22 and then with three new HFC fluids: R417A, R422A and R422D. The investigation verified that despite the case of substitution and the advantage of being able to continue to use mineral oil as a lubricant in the compressor, the performance with the new tested fluids did not result as efficient as when using R22.
2011
Settore ING-IND/10 - Fisica Tecnica Industriale
La Rocca, V., Panno, G. (2011). Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants. APPLIED ENERGY, Volume 88, Issue 8, August 2011(Issue 8), 2809-2815 [10.1016/j.apenergy.2011.01.051Document].
File in questo prodotto:
File Dimensione Formato  
La Rocca et al - Experimental performance evaluation of a vapour compression.pdf

Solo gestori archvio

Dimensione 700.92 kB
Formato Adobe PDF
700.92 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/76114
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 66
  • ???jsp.display-item.citation.isi??? 48
social impact