The purpose of the present work is to show the validation of a new model to simulate the physical phenomenon of partial discharge (PD) produced in air voids inside insulating epoxy resin. The model has been developed on the basis of a new approach that combines the known circuit model of three capacitors with a model used to describe the behavior of the ionized channel inside of the inclusion during the discharge phenomenon, short-circuiting the capacity that represents the void. The approach is based on time-variable conductance of the void, subjected to multistress conditions: voltage, temperature and pressure. The new approach has been developed from a time variable conductivity model used for the study of the discharge with dielectric barrier (DBD). The different parameters which influence the discharge phenomenon in the void are taken into account through an approach in which a lumped circuit is used to simulate the effects of global PD asset. The results of the multiple simulations have been compared with experimental and simulated behaviors found in the literature on the subject.

Di Silvestre, M.L., Miceli, R., Romano, P., Viola, F. (2013). Simplified Hybrid PD Model in Voids: Pattern Validation. In 2013 IV International Conference on Power Engineering, Energy and Electrical Drives (POWERENG) - IEEE Explore (pp.1807-1813). IEEE [10.1109/PowerEng.2013.6635892].

Simplified Hybrid PD Model in Voids: Pattern Validation

DI SILVESTRE, Maria Luisa;MICELI, Rosario;ROMANO, Pietro;VIOLA, Fabio
2013-01-01

Abstract

The purpose of the present work is to show the validation of a new model to simulate the physical phenomenon of partial discharge (PD) produced in air voids inside insulating epoxy resin. The model has been developed on the basis of a new approach that combines the known circuit model of three capacitors with a model used to describe the behavior of the ionized channel inside of the inclusion during the discharge phenomenon, short-circuiting the capacity that represents the void. The approach is based on time-variable conductance of the void, subjected to multistress conditions: voltage, temperature and pressure. The new approach has been developed from a time variable conductivity model used for the study of the discharge with dielectric barrier (DBD). The different parameters which influence the discharge phenomenon in the void are taken into account through an approach in which a lumped circuit is used to simulate the effects of global PD asset. The results of the multiple simulations have been compared with experimental and simulated behaviors found in the literature on the subject.
Settore ING-IND/31 - Elettrotecnica
Settore ING-IND/32 - Convertitori, Macchine E Azionamenti Elettrici
15-mag-2013
Power Engeneering, Energy, Electrical Drives - POWERENG2013
Instambul, Turchia
13-17 maggio 2013
4th
apr-2013
2013
7
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6635892&newsearch=true&queryText=Simplified%20Hybrid%20PD%20Model%20in%20Voids:%20Pattern%20Validation
ISSN : 2155-5516 INSPEC Accession Number: 13860820
Di Silvestre, M.L., Miceli, R., Romano, P., Viola, F. (2013). Simplified Hybrid PD Model in Voids: Pattern Validation. In 2013 IV International Conference on Power Engineering, Energy and Electrical Drives (POWERENG) - IEEE Explore (pp.1807-1813). IEEE [10.1109/PowerEng.2013.6635892].
Proceedings (atti dei congressi)
Di Silvestre, ML; Miceli, R; Romano, P; Viola, F
File in questo prodotto:
File Dimensione Formato  
06635892.pdf

Solo gestori archvio

Descrizione: Articolo completo
Dimensione 389.96 kB
Formato Adobe PDF
389.96 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/73006
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? ND
social impact