The aim of this paper is to characterize oil-filled power transformers in the narrow-band power-line communication (PLC) frequency range of 50–150 kHz. A new model is proposed for such type of a transformer, in the aforementioned frequency range of interest, in order to study its influence on the signal transmission and to investigate the possibility that the PLC signal can cross the power transformer itself. The new model is simpler than those previously proposed in literature, and it can be used in the whole frequency range available for NB PLC according to the CENELEC EN 50065-1 A-band. In order to validate the model, simulation and measurement results are compared for four oil-filled power transformers with different rated power values. A complete PLC system in the case of a medium-voltage (MV) power network is also simulated, in order to perform a preliminary evaluation of the influence of power transformers on the communication system. The MV overhead power line, the oil-filled power transformers, the MV signal coupling network, and two ST7540 frequency shift keying (FSK) power-line transceivers are included in the simulated system. The performances of the complete PLC communication system are evaluated in the case of both MV to low voltage (LV) and LV toMV transmissions. The analysis is carried out by evaluating the signal attenuation, which is computed as the ratio between the received and transmitted voltage signals, in the case of different line lengths and carrier frequency values.

Cataliotti, A., Cosentino, V., Di Cara, D., Tinè, G. (2012). Oil filled MV/LV Power Transformer Behavior in Narrow Band Power Line Communication Systems. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 61, No 10, 2642-2652 [10.1109/TIM.2012.2209911].

Oil filled MV/LV Power Transformer Behavior in Narrow Band Power Line Communication Systems

CATALIOTTI, Antonio;COSENTINO, Valentina;DI CARA, Dario;
2012-01-01

Abstract

The aim of this paper is to characterize oil-filled power transformers in the narrow-band power-line communication (PLC) frequency range of 50–150 kHz. A new model is proposed for such type of a transformer, in the aforementioned frequency range of interest, in order to study its influence on the signal transmission and to investigate the possibility that the PLC signal can cross the power transformer itself. The new model is simpler than those previously proposed in literature, and it can be used in the whole frequency range available for NB PLC according to the CENELEC EN 50065-1 A-band. In order to validate the model, simulation and measurement results are compared for four oil-filled power transformers with different rated power values. A complete PLC system in the case of a medium-voltage (MV) power network is also simulated, in order to perform a preliminary evaluation of the influence of power transformers on the communication system. The MV overhead power line, the oil-filled power transformers, the MV signal coupling network, and two ST7540 frequency shift keying (FSK) power-line transceivers are included in the simulated system. The performances of the complete PLC communication system are evaluated in the case of both MV to low voltage (LV) and LV toMV transmissions. The analysis is carried out by evaluating the signal attenuation, which is computed as the ratio between the received and transmitted voltage signals, in the case of different line lengths and carrier frequency values.
2012
Settore ING-INF/07 - Misure Elettriche E Elettroniche
Cataliotti, A., Cosentino, V., Di Cara, D., Tinè, G. (2012). Oil filled MV/LV Power Transformer Behavior in Narrow Band Power Line Communication Systems. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 61, No 10, 2642-2652 [10.1109/TIM.2012.2209911].
File in questo prodotto:
File Dimensione Formato  
TIM12_Oil filled MV-LV power transformer behavior_.pdf

Solo gestori archvio

Dimensione 1.87 MB
Formato Adobe PDF
1.87 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/64373
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 50
  • ???jsp.display-item.citation.isi??? 36
social impact