In this paper, the authors propose a new protection strategy for electrical Medium Voltage distribution networks, based on a distributed intelligence system composed of a central unit and of many local processing units. The distributed intelligence system can precisely identify and locate faults in suitably limited times. Each local processing unit is composed of a data acquisition system and a data analysis system. The first allows the accurate reconstruction of the fundamental using only 1.5 cycles of under fault transient electrical quantities. The second performs suitably precise on-line fault diagnosis based on the data provided by the data acquisition module. The data acquisition algorithm and the data analysis algorithm are managed by the data processing system of the remote processing units implemented on a micro-processor. With the proposed architecture, if local acquisition, elaboration and clearing times are limited, the faulted line experiences only two micro-interruptions, also during multi-phase permanent faults, with a great improvement of the quality of the service. Some experimental results on a simulated test system, proving the efficacy and simplicity of the proposed approach, are reported.

Campoccia, A., Cataliotti, A., Corso, G., Cosentino, V., Di Silvestre, M.L., Riva Sanseverino, E., et al. (2010). A New Protection Strategy for Electrical Distribution Systems. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING, 5(n.5), 2224-2233.

A New Protection Strategy for Electrical Distribution Systems

CAMPOCCIA, Angelo;CATALIOTTI, Antonio;CORSO, Gioacchino;COSENTINO, Valentina;DI SILVESTRE, Maria Luisa;RIVA SANSEVERINO, Eleonora;ZIZZO, Gaetano
2010-01-01

Abstract

In this paper, the authors propose a new protection strategy for electrical Medium Voltage distribution networks, based on a distributed intelligence system composed of a central unit and of many local processing units. The distributed intelligence system can precisely identify and locate faults in suitably limited times. Each local processing unit is composed of a data acquisition system and a data analysis system. The first allows the accurate reconstruction of the fundamental using only 1.5 cycles of under fault transient electrical quantities. The second performs suitably precise on-line fault diagnosis based on the data provided by the data acquisition module. The data acquisition algorithm and the data analysis algorithm are managed by the data processing system of the remote processing units implemented on a micro-processor. With the proposed architecture, if local acquisition, elaboration and clearing times are limited, the faulted line experiences only two micro-interruptions, also during multi-phase permanent faults, with a great improvement of the quality of the service. Some experimental results on a simulated test system, proving the efficacy and simplicity of the proposed approach, are reported.
2010
Settore ING-IND/33 - Sistemi Elettrici Per L'Energia
Settore ING-IND/31 - Elettrotecnica
Settore ING-INF/07 - Misure Elettriche E Elettroniche
Campoccia, A., Cataliotti, A., Corso, G., Cosentino, V., Di Silvestre, M.L., Riva Sanseverino, E., et al. (2010). A New Protection Strategy for Electrical Distribution Systems. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING, 5(n.5), 2224-2233.
File in questo prodotto:
File Dimensione Formato  
IREE_12_04_10_E.pdf

Solo gestori archvio

Descrizione: articolo principale
Dimensione 154.3 kB
Formato Adobe PDF
154.3 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/54100
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact