The case-study of a steel bowstring bridge set in a marine environment and highly damaged by corrosion is presented. The bridge was built in 2004 and was repainted for corrosion protection in 2010. Despite the recent construction and the maintenance interventions, many structural elements like hangers are highly damaged by corrosion with decreasing performance in terms of serviceability and ultimate limit states. A deep investigation was carried out in order to assess the bridge and to establish the necessary retrofit actions to be carried out in the near future. In-situ tests reveal the reduced performance of the original steel in terms of strength and corrosion protection, together with the inefficiency of the successive maintenance interventions. The paper presents assessment of the bridge and retrofit measures, including replacement of the hangers and galvanization through thermal spray coating technology, in order to increase its service life. The results of the investigations and the intervention measures are outlined and discussed.

Granata, M.F. (2020). Effects of corrosion on a steel bowstring bridge in marine environment: A case-study of assessment and retrofit. BRIDGE STRUCTURES, 16(4), 121-137 [10.3233/BRS-200178].

Effects of corrosion on a steel bowstring bridge in marine environment: A case-study of assessment and retrofit

Granata, Michele Fabio
2020-01-01

Abstract

The case-study of a steel bowstring bridge set in a marine environment and highly damaged by corrosion is presented. The bridge was built in 2004 and was repainted for corrosion protection in 2010. Despite the recent construction and the maintenance interventions, many structural elements like hangers are highly damaged by corrosion with decreasing performance in terms of serviceability and ultimate limit states. A deep investigation was carried out in order to assess the bridge and to establish the necessary retrofit actions to be carried out in the near future. In-situ tests reveal the reduced performance of the original steel in terms of strength and corrosion protection, together with the inefficiency of the successive maintenance interventions. The paper presents assessment of the bridge and retrofit measures, including replacement of the hangers and galvanization through thermal spray coating technology, in order to increase its service life. The results of the investigations and the intervention measures are outlined and discussed.
2020
Granata, M.F. (2020). Effects of corrosion on a steel bowstring bridge in marine environment: A case-study of assessment and retrofit. BRIDGE STRUCTURES, 16(4), 121-137 [10.3233/BRS-200178].
File in questo prodotto:
File Dimensione Formato  
2020 - Bridge Structures ponte Mazara.pdf

Solo gestori archvio

Descrizione: article in press
Tipologia: Versione Editoriale
Dimensione 3.06 MB
Formato Adobe PDF
3.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Granata-Paper_bowstring_Bridge_Sicily_rev3.pdf

accesso aperto

Descrizione: Articolo
Tipologia: Pre-print
Dimensione 2.41 MB
Formato Adobe PDF
2.41 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/506525
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact