Ascending thoracic aortic aneurysm (ATAA) is among the most devastating forms of cardiovascular disease, causing a significant mortality despite current medical and surgical treatments [1]. Moreover these therapies themselves are associated with great risk of mortality or morbidity, complicated by the advanced age of the typical patient, and high surgical costs. The mechanics of spontaneous aortic dissection is not fully understood. It is generally believed that aortic dissection initiates as an intimal tear in which a separation of wall layers produces the formation of a ‘false’ lumen. The dissection may propagate axially and/or circumferentially due to blood flow and pressure. Dissection may lead to several possible complications. For example, the septum between the false lumen and true lumen may fracture, resulting in embolism and ischemic damage. Another possibility is that the thinned and weakened residual outer aortic wall may fail, resulting in rapid blood loss and tamponade. From a mechanical point of view, aortic dissection is due to the combination of hemodynamic loads acting on the intimal layer and the laminar structure of the aortic wall with different elastic properties. Since the aorta is an anisotropic and inhomogeneous body, it is possible that the hemodynamic loads (including mural shear) produce stresses of the appropriate types and magnitudes that result in delamination of the aortic layers [2]. That is, dissection initiates when the hemodynamic loads overcome the adhesive forces holding the layers together. The effects of the loads are of course accentuated in the case of a disorganized microstructure and degenerated tissue that is typical in aneurysmal disease. The goal of this study was to perform a preliminary investigation of the dissection properties of human ATAA tissues. Specifically, delamination tests were designed and carried out on nonaneurysmal and aneurysmal thoracic tissues with bicuspid (BAV) and tricuspid (TAV) aortic valves. The possible influence of the tissue anisotropy on these properties was investigated by testing oriented specimen strips. Finally, the morphology of the delamination surfaces was studied with scanning electron microscopy (SEM).

Pasta, S., Philippi, J.A., Gleason, T.G., Vorp, D.A. (2010). DISSECTION PROPERTIES OF ANEURYSMAL AND NONANEURYSMAL HUMAN ASCENDING THORACIC AORTA: PRELIMINARY RESULTS. In ASME 2010 Summer Bioengineering Conference, SBC 2010 (pp. 9-10) [10.1115/SBC2010-19520].

DISSECTION PROPERTIES OF ANEURYSMAL AND NONANEURYSMAL HUMAN ASCENDING THORACIC AORTA: PRELIMINARY RESULTS

PASTA, Salvatore;
2010-01-01

Abstract

Ascending thoracic aortic aneurysm (ATAA) is among the most devastating forms of cardiovascular disease, causing a significant mortality despite current medical and surgical treatments [1]. Moreover these therapies themselves are associated with great risk of mortality or morbidity, complicated by the advanced age of the typical patient, and high surgical costs. The mechanics of spontaneous aortic dissection is not fully understood. It is generally believed that aortic dissection initiates as an intimal tear in which a separation of wall layers produces the formation of a ‘false’ lumen. The dissection may propagate axially and/or circumferentially due to blood flow and pressure. Dissection may lead to several possible complications. For example, the septum between the false lumen and true lumen may fracture, resulting in embolism and ischemic damage. Another possibility is that the thinned and weakened residual outer aortic wall may fail, resulting in rapid blood loss and tamponade. From a mechanical point of view, aortic dissection is due to the combination of hemodynamic loads acting on the intimal layer and the laminar structure of the aortic wall with different elastic properties. Since the aorta is an anisotropic and inhomogeneous body, it is possible that the hemodynamic loads (including mural shear) produce stresses of the appropriate types and magnitudes that result in delamination of the aortic layers [2]. That is, dissection initiates when the hemodynamic loads overcome the adhesive forces holding the layers together. The effects of the loads are of course accentuated in the case of a disorganized microstructure and degenerated tissue that is typical in aneurysmal disease. The goal of this study was to perform a preliminary investigation of the dissection properties of human ATAA tissues. Specifically, delamination tests were designed and carried out on nonaneurysmal and aneurysmal thoracic tissues with bicuspid (BAV) and tricuspid (TAV) aortic valves. The possible influence of the tissue anisotropy on these properties was investigated by testing oriented specimen strips. Finally, the morphology of the delamination surfaces was studied with scanning electron microscopy (SEM).
2010
Thoracic aortic aneurysm, dissection
978-079184403-8
Pasta, S., Philippi, J.A., Gleason, T.G., Vorp, D.A. (2010). DISSECTION PROPERTIES OF ANEURYSMAL AND NONANEURYSMAL HUMAN ASCENDING THORACIC AORTA: PRELIMINARY RESULTS. In ASME 2010 Summer Bioengineering Conference, SBC 2010 (pp. 9-10) [10.1115/SBC2010-19520].
File in questo prodotto:
File Dimensione Formato  
Dissection properties of aneurysmal and nonaneurysmal human ascending thoracic aorta preliminary results.pdf

Solo gestori archvio

Dimensione 833.33 kB
Formato Adobe PDF
833.33 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/45081
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact