Increased oxidative burden contributes to the pathogenesis of most inflammatory diseases and is associated with aging and chronic inflammation. Macrophages contribute to the generation of reactive oxygen species (ROS) within inflamed tissues. Currently, ROS generation is measured using fluorescent probes and colorimetric/fluorimetric biochemical assays. Hydrogen peroxide (H2O2) diffuses through the cell membrane and can be monitored in the extracellular space. Herein, we present a sensor for H2O2 detection released by cells in culture supernatants. H2O2 sensing performance was evaluated using chronoamperometric detection. A sensitivity of 0.0641 μA μM−1 cm−2 with a limit of detection of 6.55 μM and excellent selectivity against many interferents was found. H2O2 release was also measured in conditioned medium from human THP-1 macrophages exposed to pro-oxidant and anti-oxidant treatments. The results were compared with those obtained by flow cytometry using the same cells stained with carboxy-H2DCFDA and MitoSOX Red, which detect intracellular ROS and mitochondrial superoxide, respectively. The addition of pro-oxidants lipopolysaccharide (LPS) and nigericin resulted in a significant increase in the cathodic current due to the H2O2 reduction, indicating an increased release of H2O2. The addition of 17-oxo-DHA, which inhibits LPS- and nigericin-dependent responses, decreased the LPS- and nigericin-induced release of H2O2. All the results obtained with the sensor were consistent with those obtained using flow cytometry. The operation of the sensor directly in the cell culture growth medium had no impact on cell viability. The sensor is highly sensitive, fast, and cost effective, and it can potentially be used for real time monitoring of oxidative stress.

Patella B., Buscetta M., Di Vincenzo S., Ferraro M., Aiello G., Sunseri C., et al. (2021). Electrochemical sensor based on rGO/Au nanoparticles for monitoring H2O2 released by human macrophages. SENSORS AND ACTUATORS. B, CHEMICAL, 327, 128901-1-128901-11 [10.1016/j.snb.2020.128901].

Electrochemical sensor based on rGO/Au nanoparticles for monitoring H2O2 released by human macrophages

Patella B.
Membro del Collaboration Group
;
Aiello G.
Membro del Collaboration Group
;
Sunseri C.
Membro del Collaboration Group
;
Inguanta R.
Membro del Collaboration Group
;
2021-01-01

Abstract

Increased oxidative burden contributes to the pathogenesis of most inflammatory diseases and is associated with aging and chronic inflammation. Macrophages contribute to the generation of reactive oxygen species (ROS) within inflamed tissues. Currently, ROS generation is measured using fluorescent probes and colorimetric/fluorimetric biochemical assays. Hydrogen peroxide (H2O2) diffuses through the cell membrane and can be monitored in the extracellular space. Herein, we present a sensor for H2O2 detection released by cells in culture supernatants. H2O2 sensing performance was evaluated using chronoamperometric detection. A sensitivity of 0.0641 μA μM−1 cm−2 with a limit of detection of 6.55 μM and excellent selectivity against many interferents was found. H2O2 release was also measured in conditioned medium from human THP-1 macrophages exposed to pro-oxidant and anti-oxidant treatments. The results were compared with those obtained by flow cytometry using the same cells stained with carboxy-H2DCFDA and MitoSOX Red, which detect intracellular ROS and mitochondrial superoxide, respectively. The addition of pro-oxidants lipopolysaccharide (LPS) and nigericin resulted in a significant increase in the cathodic current due to the H2O2 reduction, indicating an increased release of H2O2. The addition of 17-oxo-DHA, which inhibits LPS- and nigericin-dependent responses, decreased the LPS- and nigericin-induced release of H2O2. All the results obtained with the sensor were consistent with those obtained using flow cytometry. The operation of the sensor directly in the cell culture growth medium had no impact on cell viability. The sensor is highly sensitive, fast, and cost effective, and it can potentially be used for real time monitoring of oxidative stress.
2021
Settore ING-IND/23 - Chimica Fisica Applicata
Settore ING-IND/17 - Impianti Industriali Meccanici
Patella B., Buscetta M., Di Vincenzo S., Ferraro M., Aiello G., Sunseri C., et al. (2021). Electrochemical sensor based on rGO/Au nanoparticles for monitoring H2O2 released by human macrophages. SENSORS AND ACTUATORS. B, CHEMICAL, 327, 128901-1-128901-11 [10.1016/j.snb.2020.128901].
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S092540052031248X-main.pdf

Solo gestori archvio

Tipologia: Post-print
Dimensione 3.86 MB
Formato Adobe PDF
3.86 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/435787
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 80
  • ???jsp.display-item.citation.isi??? 73
social impact