Indium tin oxide (ITO) coated on flexible polyethylene terephthalate (PET) substrate electrode was modified with reduced graphene oxide and gold nanoparticles by simple co-electrodeposition performed at -0.8 V vs SCE for 200 s. All samples were characterized by electron scan microscopy. The as prepared electrode was used as electrochemical sensor to selective detection of ascorbic acid using linear sweep voltammetry. Excellent results were obtained in a linear range from 20 to 150 μM of ascorbic acid with a limit of detection of about 3.1 μM (S/N=3.3). The sensors have a reproducibility of about 5.5% and also show high selectivity towards different interferents such as chlorine, calcium, magnesium, sulphate ions, sodium and glucose. Ascorbic acid was detected also in milk samples demonstrating the possibility quantify this analyte in real samples with a very cheap method.

Mazzara F., Patella B., Aiello G., Sunseri C., Inguanta R. (2020). Ascorbic Acid determination using linear sweep voltammetry on flexible electrode modified with gold nanoparticles and reduced graphene oxide. In IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE (pp. 406-410). Institute of Electrical and Electronics Engineers Inc. [10.1109/MELECON48756.2020.9140684].

Ascorbic Acid determination using linear sweep voltammetry on flexible electrode modified with gold nanoparticles and reduced graphene oxide

Mazzara F.
Membro del Collaboration Group
;
Patella B.
Membro del Collaboration Group
;
Aiello G.
Membro del Collaboration Group
;
Sunseri C.
Membro del Collaboration Group
;
Inguanta R.
Membro del Collaboration Group
2020-01-01

Abstract

Indium tin oxide (ITO) coated on flexible polyethylene terephthalate (PET) substrate electrode was modified with reduced graphene oxide and gold nanoparticles by simple co-electrodeposition performed at -0.8 V vs SCE for 200 s. All samples were characterized by electron scan microscopy. The as prepared electrode was used as electrochemical sensor to selective detection of ascorbic acid using linear sweep voltammetry. Excellent results were obtained in a linear range from 20 to 150 μM of ascorbic acid with a limit of detection of about 3.1 μM (S/N=3.3). The sensors have a reproducibility of about 5.5% and also show high selectivity towards different interferents such as chlorine, calcium, magnesium, sulphate ions, sodium and glucose. Ascorbic acid was detected also in milk samples demonstrating the possibility quantify this analyte in real samples with a very cheap method.
2020
Settore ING-IND/23 - Chimica Fisica Applicata
Settore ING-IND/17 - Impianti Industriali Meccanici
978-1-7281-5200-4
Mazzara F., Patella B., Aiello G., Sunseri C., Inguanta R. (2020). Ascorbic Acid determination using linear sweep voltammetry on flexible electrode modified with gold nanoparticles and reduced graphene oxide. In IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE (pp. 406-410). Institute of Electrical and Electronics Engineers Inc. [10.1109/MELECON48756.2020.9140684].
File in questo prodotto:
File Dimensione Formato  
IEEE Xplore Full-Text PDF:MAZZARA.pdf

Solo gestori archvio

Tipologia: Post-print
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/430753
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact