The recent advances in multiparametric monitoring of biosignals and management of big data prompt for the development of devices and techniques for the extraction of indicators with physiological relevance. In this context, we have designed and realized a portable electronic system, equipped with simple biomedical sensors, able to synchronously record multiple electrocardiographic (ECG), photoplethysmographic (PPG) and breathing signals, for carrying out a non-invasive monitoring of several cardiovascular parameters. In this work, we show the results of preliminary measurements performed following a specific physiological protocol (i.e., deep breathing with 10 s per cycle). The system allows to monitor specific physiological behaviors, such as the decrease of the R-R interval (increase of the heart rate) during inhalation and the increase of the stroke volume increases during exhalation. The high quality of the ECG/PPG/breath waveforms acquired by our probes, sensors and system allows an improvement in the accuracy of the extraction of noteworthy cardiovascular parameters.

Pernice, R., Parisi, A., Guarino, S., Fallica, G., Vinciguerra, V., Ferla, G., et al. (2020). Low invasive multisensor acquisition system for real-time monitoring of cardiovascular and respiratory parameters. In 2020 IEEE 20th Mediterranean Electrotechnical Conference (MELECON) (pp. 306-310) [10.1109/MELECON48756.2020.9140716].

Low invasive multisensor acquisition system for real-time monitoring of cardiovascular and respiratory parameters

Pernice, Riccardo
;
Parisi, Antonino;Guarino, Saverio;Faes, Luca;Busacca, Alessandro
2020-01-01

Abstract

The recent advances in multiparametric monitoring of biosignals and management of big data prompt for the development of devices and techniques for the extraction of indicators with physiological relevance. In this context, we have designed and realized a portable electronic system, equipped with simple biomedical sensors, able to synchronously record multiple electrocardiographic (ECG), photoplethysmographic (PPG) and breathing signals, for carrying out a non-invasive monitoring of several cardiovascular parameters. In this work, we show the results of preliminary measurements performed following a specific physiological protocol (i.e., deep breathing with 10 s per cycle). The system allows to monitor specific physiological behaviors, such as the decrease of the R-R interval (increase of the heart rate) during inhalation and the increase of the stroke volume increases during exhalation. The high quality of the ECG/PPG/breath waveforms acquired by our probes, sensors and system allows an improvement in the accuracy of the extraction of noteworthy cardiovascular parameters.
2020
Settore ING-INF/01 - Elettronica
Settore ING-INF/06 - Bioingegneria Elettronica E Informatica
978-1-7281-5200-4
Pernice, R., Parisi, A., Guarino, S., Fallica, G., Vinciguerra, V., Ferla, G., et al. (2020). Low invasive multisensor acquisition system for real-time monitoring of cardiovascular and respiratory parameters. In 2020 IEEE 20th Mediterranean Electrotechnical Conference (MELECON) (pp. 306-310) [10.1109/MELECON48756.2020.9140716].
File in questo prodotto:
File Dimensione Formato  
2020_Pernice_MELECON2020_published.pdf

Solo gestori archvio

Descrizione: Articolo pubblicato
Tipologia: Versione Editoriale
Dimensione 1.17 MB
Formato Adobe PDF
1.17 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
2020_Pernice_MELECON2020_postprint.pdf

accesso aperto

Descrizione: Post-print
Tipologia: Post-print
Dimensione 622.81 kB
Formato Adobe PDF
622.81 kB Adobe PDF Visualizza/Apri