The current generation of transcatheter heart valves (THV), as the Edwards SAPIEN 3 Ultra (S3), is not specifically designed for mitral position implantation and has intrinsic design geometry that may make mitral implantation suboptimal. This study aimed to develop a computed-tomography (CT) based CAD workflow for the preoperative planning of transcatheter mitral valve replacement (TMVR) by evaluating the resulting obstruction in the left ventricular outflow tract (LVOT). Specifically, the computational framework to reconstruct heart anatomy and virtually deploy the THV into mitral valve annulus was developed and successively applied to the cases of two patients who experienced annuloplasty ring failure. Planimetric assessment of the cross-sectional area of the neo-LVOT was quantified at different anatomic levels of implanted THV. Findings revealed the importance of the proposed CAD modeling workflow to enable more informative pre-operative assessments of the risk related to the development of the neo-LVOT obstruction and even to guide the Heart Team regarding device selection, sizing and intended positioning for TMVR.

Pasta S., Cannata S., Gentile G., Ingrassia T., Nigrelli V., Gandolfo C. (2020). CAD Modeling for Evaluating LVOT Obstruction in Transcatheter Mitral Valve Replacement. In Lecture Notes in Mechanical Engineering (pp. 776-787). Springer [10.1007/978-3-030-31154-4_66].

CAD Modeling for Evaluating LVOT Obstruction in Transcatheter Mitral Valve Replacement

Pasta S.
;
Ingrassia T.;Nigrelli V.;
2020-01-01

Abstract

The current generation of transcatheter heart valves (THV), as the Edwards SAPIEN 3 Ultra (S3), is not specifically designed for mitral position implantation and has intrinsic design geometry that may make mitral implantation suboptimal. This study aimed to develop a computed-tomography (CT) based CAD workflow for the preoperative planning of transcatheter mitral valve replacement (TMVR) by evaluating the resulting obstruction in the left ventricular outflow tract (LVOT). Specifically, the computational framework to reconstruct heart anatomy and virtually deploy the THV into mitral valve annulus was developed and successively applied to the cases of two patients who experienced annuloplasty ring failure. Planimetric assessment of the cross-sectional area of the neo-LVOT was quantified at different anatomic levels of implanted THV. Findings revealed the importance of the proposed CAD modeling workflow to enable more informative pre-operative assessments of the risk related to the development of the neo-LVOT obstruction and even to guide the Heart Team regarding device selection, sizing and intended positioning for TMVR.
2020
978-3-030-31153-7
978-3-030-31154-4
Pasta S., Cannata S., Gentile G., Ingrassia T., Nigrelli V., Gandolfo C. (2020). CAD Modeling for Evaluating LVOT Obstruction in Transcatheter Mitral Valve Replacement. In Lecture Notes in Mechanical Engineering (pp. 776-787). Springer [10.1007/978-3-030-31154-4_66].
File in questo prodotto:
File Dimensione Formato  
_488383_1_En_66_Chapter_Author.pdf

Solo gestori archvio

Tipologia: Pre-print
Dimensione 5.2 MB
Formato Adobe PDF
5.2 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/403903
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact