Within the framework of the Work Package DIV 1 – “Divertor Cassette Design and Integration” of the EUROfusion action, a research campaign has been jointly carried out by University of Palermo and ENEA to investigate the steady state thermal-hydraulic behaviour of the DEMO divertor cassette cooling circuit, focussing the attention on its Plasma Facing Components (PFCs). The research campaign has been carried out following a theoretical-computational approach based on the Finite Volume Method and adopting the commercial Computational Fluid-Dynamic code ANSYS-CFX. A realistic model of the PFCs cooling circuit has been analysed, specifically embedding each Plasma Facing Unit (PFU) cooling channel with the foreseen swirl tape turbulence promoter, hence resulting in a finite volume model much more detailed than those assessed in previous analyses. Its thermal-hydraulic performances have been numerically evaluated under nominal steady state conditions, also comparing the obtained results with the corresponding outcomes of analogous analyses carried out for a simplified PFCs configuration, without swirl tapes. Moreover, the main thermal-hydraulic parameters have been evaluated in order to check whether the considered PFCs cooling circuit might fulfil the total pressure drop requirement (Δp <1.4 MPa), providing a uniform cooling of the Vertical Target PFU channels with a viable CHF margin (>1.4). The PFCs cooling circuit thermal-hydraulic behaviour has been additionally assessed at alternative operative conditions, issued to check the viability of a coolant velocity reduction, in order to minimize corrosion and vibrations inside the PFU channels. Models, loads and boundary conditions assumed for the analyses are herewith reported and critically discussed, together with the main results obtained.

Di Maio P.A., Garitta S., You J.H., Mazzone G., Vallone E. (2019). Hydraulic analysis of EU-DEMO divertor plasma facing components cooling circuit under nominal operating scenarios. FUSION ENGINEERING AND DESIGN, 146, 1764-1768 [10.1016/j.fusengdes.2019.03.030].

Hydraulic analysis of EU-DEMO divertor plasma facing components cooling circuit under nominal operating scenarios

Di Maio P. A.;Garitta S.;Vallone E.
2019-01-01

Abstract

Within the framework of the Work Package DIV 1 – “Divertor Cassette Design and Integration” of the EUROfusion action, a research campaign has been jointly carried out by University of Palermo and ENEA to investigate the steady state thermal-hydraulic behaviour of the DEMO divertor cassette cooling circuit, focussing the attention on its Plasma Facing Components (PFCs). The research campaign has been carried out following a theoretical-computational approach based on the Finite Volume Method and adopting the commercial Computational Fluid-Dynamic code ANSYS-CFX. A realistic model of the PFCs cooling circuit has been analysed, specifically embedding each Plasma Facing Unit (PFU) cooling channel with the foreseen swirl tape turbulence promoter, hence resulting in a finite volume model much more detailed than those assessed in previous analyses. Its thermal-hydraulic performances have been numerically evaluated under nominal steady state conditions, also comparing the obtained results with the corresponding outcomes of analogous analyses carried out for a simplified PFCs configuration, without swirl tapes. Moreover, the main thermal-hydraulic parameters have been evaluated in order to check whether the considered PFCs cooling circuit might fulfil the total pressure drop requirement (Δp <1.4 MPa), providing a uniform cooling of the Vertical Target PFU channels with a viable CHF margin (>1.4). The PFCs cooling circuit thermal-hydraulic behaviour has been additionally assessed at alternative operative conditions, issued to check the viability of a coolant velocity reduction, in order to minimize corrosion and vibrations inside the PFU channels. Models, loads and boundary conditions assumed for the analyses are herewith reported and critically discussed, together with the main results obtained.
2019
Settore ING-IND/19 - Impianti Nucleari
Di Maio P.A., Garitta S., You J.H., Mazzone G., Vallone E. (2019). Hydraulic analysis of EU-DEMO divertor plasma facing components cooling circuit under nominal operating scenarios. FUSION ENGINEERING AND DESIGN, 146, 1764-1768 [10.1016/j.fusengdes.2019.03.030].
File in questo prodotto:
File Dimensione Formato  
RI-86.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 860.84 kB
Formato Adobe PDF
860.84 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
DiMaio_Hydraulic.pdf

Solo gestori archvio

Dimensione 472.9 kB
Formato Adobe PDF
472.9 kB Adobe PDF   Visualizza/Apri   Richiedi una copia