In the present paper, the safety conditions of reinforced concrete (RC) balconies subject to degradation phenomena caused by carbonation, presence of chlorides or water infiltration were examined. After a brief review of the typical damages of balconies occurring with detachments of plaster and bricks expulsion, some cases of collapses of balconies recently occurred were presented. Therefore, a calculation model was proposed for a hand verification of the flexural and shear strength of existing corroded T beams cast in place of lightened RC orthotropic slabs forming the balcony and for the calculus of deflection including slippage of steel bars. Diffused and pitting corrosion on steel bars, compressive concrete strength degradation, and concrete bond strength degradation are included in the model. This approach is simple and can be applied based on the experimental information available (carbonation test, chloride content, measurement of the pitting in the bar, a gravimetric method for general corrosion) or by utilizing analytical expressions calibrated on knowledge of the corrosion current intensity determined by linear polarization resistance measurement (LPR).

Campione G., Cannella F. (2019). Risk of failure in existing RC balcony and strength verification under degradation phenomena. ENGINEERING FAILURE ANALYSIS, 109 [10.1016/j.engfailanal.2019.104248].

Risk of failure in existing RC balcony and strength verification under degradation phenomena

Campione G.
Membro del Collaboration Group
;
Cannella F.
Membro del Collaboration Group
2019-01-01

Abstract

In the present paper, the safety conditions of reinforced concrete (RC) balconies subject to degradation phenomena caused by carbonation, presence of chlorides or water infiltration were examined. After a brief review of the typical damages of balconies occurring with detachments of plaster and bricks expulsion, some cases of collapses of balconies recently occurred were presented. Therefore, a calculation model was proposed for a hand verification of the flexural and shear strength of existing corroded T beams cast in place of lightened RC orthotropic slabs forming the balcony and for the calculus of deflection including slippage of steel bars. Diffused and pitting corrosion on steel bars, compressive concrete strength degradation, and concrete bond strength degradation are included in the model. This approach is simple and can be applied based on the experimental information available (carbonation test, chloride content, measurement of the pitting in the bar, a gravimetric method for general corrosion) or by utilizing analytical expressions calibrated on knowledge of the corrosion current intensity determined by linear polarization resistance measurement (LPR).
2019
Settore ICAR/09 - Tecnica Delle Costruzioni
Campione G., Cannella F. (2019). Risk of failure in existing RC balcony and strength verification under degradation phenomena. ENGINEERING FAILURE ANALYSIS, 109 [10.1016/j.engfailanal.2019.104248].
File in questo prodotto:
File Dimensione Formato  
Risk.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/389162
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact