This paper aims at characterizing and improving the metrological performances of current and voltage instrument transformers (CTs and VTs) in harmonic measurements in the power system. A theoretical analysis is carried out to demonstrate that, due to the iron core nonlinearity, CT and VT output signal is distorted even when the input signal is a pure sine wave. Starting from this analysis, a new method for CT and VT characterization and compensation is proposed. In a first step, they are characterized in sinusoidal conditions and the harmonic phasors of the distorted output are measured; in the second step, these phasors are used to compensate the harmonic phasors measured in normal operating conditions, which are typically distorted. The proposed characterization and compensation techniques are called SINusoidal characterization for DIstortion COMPensation (SINDICOMP). Several experimental tests, using high-accuracy calibration setups, have been performed to verify the proposed methods. The experimental results showed that the SINDICOMP technique assures a significant improvement of CT and VT metrological performances in harmonic measurements.

Cataliotti, A., Cosentino, V., Crotti, G., Femine, A.D., Di Cara, D., Gallo, D., et al. (2019). Compensation of Nonlinearity of Voltage and Current Instrument Transformers. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 68(5), 1322-1332 [10.1109/TIM.2018.2880060].

Compensation of Nonlinearity of Voltage and Current Instrument Transformers

Cataliotti, Antonio;Cosentino, Valentina;
2019-01-01

Abstract

This paper aims at characterizing and improving the metrological performances of current and voltage instrument transformers (CTs and VTs) in harmonic measurements in the power system. A theoretical analysis is carried out to demonstrate that, due to the iron core nonlinearity, CT and VT output signal is distorted even when the input signal is a pure sine wave. Starting from this analysis, a new method for CT and VT characterization and compensation is proposed. In a first step, they are characterized in sinusoidal conditions and the harmonic phasors of the distorted output are measured; in the second step, these phasors are used to compensate the harmonic phasors measured in normal operating conditions, which are typically distorted. The proposed characterization and compensation techniques are called SINusoidal characterization for DIstortion COMPensation (SINDICOMP). Several experimental tests, using high-accuracy calibration setups, have been performed to verify the proposed methods. The experimental results showed that the SINDICOMP technique assures a significant improvement of CT and VT metrological performances in harmonic measurements.
2019
Settore ING-INF/07 - Misure Elettriche E Elettroniche
Cataliotti, A., Cosentino, V., Crotti, G., Femine, A.D., Di Cara, D., Gallo, D., et al. (2019). Compensation of Nonlinearity of Voltage and Current Instrument Transformers. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 68(5), 1322-1332 [10.1109/TIM.2018.2880060].
File in questo prodotto:
File Dimensione Formato  
Compensation of Nonlinearity of Voltage and Current Instrument Transformers.pdf

Solo gestori archvio

Descrizione: Articolo
Tipologia: Versione Editoriale
Dimensione 3.55 MB
Formato Adobe PDF
3.55 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
compensation_non_linear_VT_19_post_pr.pdf

accesso aperto

Tipologia: Post-print
Dimensione 1.81 MB
Formato Adobe PDF
1.81 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/357146
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 67
  • ???jsp.display-item.citation.isi??? 56
social impact