The concept of load matching refers to the degree of agreement or disagreement of the on-site generation with the building load profiles: it can be increased and optimised with modifications on both the energy demand and generation. In this context, the paper presents the load match analysis of a case study: a modular housing construction (it has an area of 45 m 2 and S/V ratio equal to 2.75 m −1 ) built in Messina (Italy). Moreover, in order to optimize the design of the next test module to be built, a parametric analysis was performed considering different scenarios on the generation side, to explore the effectiveness of the solutions sets used in current design and plan different solutions for the future ones. The results show that a 4 kWh energy storage system can increase the load cover factor by 94% (to 0.78) compared to the base case (0.41), while with only a 250 W fuel cell, the load cover factor can reach the value of 0.97.

Cellura M., G.F. (2018). Analysis of Load Match in Nearly Zero Energy Buildings. In Proceedings of the 4th International Forum on Research and Technology for Society and Industry (RTSI) [10.1109/RTSI.2018.8548378].

Analysis of Load Match in Nearly Zero Energy Buildings

Cellura M.;Guarino F.;Longo S.;Tumminia G.;
2018-01-01

Abstract

The concept of load matching refers to the degree of agreement or disagreement of the on-site generation with the building load profiles: it can be increased and optimised with modifications on both the energy demand and generation. In this context, the paper presents the load match analysis of a case study: a modular housing construction (it has an area of 45 m 2 and S/V ratio equal to 2.75 m −1 ) built in Messina (Italy). Moreover, in order to optimize the design of the next test module to be built, a parametric analysis was performed considering different scenarios on the generation side, to explore the effectiveness of the solutions sets used in current design and plan different solutions for the future ones. The results show that a 4 kWh energy storage system can increase the load cover factor by 94% (to 0.78) compared to the base case (0.41), while with only a 250 W fuel cell, the load cover factor can reach the value of 0.97.
2018
Settore ING-IND/11 - Fisica Tecnica Ambientale
978-1-5386-6282-3
Cellura M., G.F. (2018). Analysis of Load Match in Nearly Zero Energy Buildings. In Proceedings of the 4th International Forum on Research and Technology for Society and Industry (RTSI) [10.1109/RTSI.2018.8548378].
File in questo prodotto:
File Dimensione Formato  
08548378.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 2 MB
Formato Adobe PDF
2 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/323849
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact