The reinforcement effect of electrical resistance strain gauges is well documented in the technical literature. In this paper the local reinforcement effect in tension is studied by using a simple theoretical model by considering a strain gauge mounted on a semi-infinite plate having the same width of the strain gauge and subjected to a uniaxial tension load. Neglecting the effect of the adhesive layer and considering the interface shear stress as an exponential distribution, the proposed model gives a closed-form solution. In detail, this model permits a simple formula to be obtained which allows the user to correct the local reinforcement effect provided that a proper calibration is performed by installing a strain gauge, of the same type as that used on the structure, on a low modulus material. Experimental evidence of the proposed method is shown. Experimental proof of the positive effect of large grid lengths on the local reinforcement effect is also reported. © IMechE 2005.

AJOVALASIT A, ZUCCARELLO B (2005). LOCAL REINFORCEMENT EFFECT OF A STRAIN GAUGE INSTALLATION ON LOW MODULUS MATERIALS. JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 40, 643-653 [10.1243/030932405X30894].

LOCAL REINFORCEMENT EFFECT OF A STRAIN GAUGE INSTALLATION ON LOW MODULUS MATERIALS

AJOVALASIT, Augusto;ZUCCARELLO, Bernardo
2005-01-01

Abstract

The reinforcement effect of electrical resistance strain gauges is well documented in the technical literature. In this paper the local reinforcement effect in tension is studied by using a simple theoretical model by considering a strain gauge mounted on a semi-infinite plate having the same width of the strain gauge and subjected to a uniaxial tension load. Neglecting the effect of the adhesive layer and considering the interface shear stress as an exponential distribution, the proposed model gives a closed-form solution. In detail, this model permits a simple formula to be obtained which allows the user to correct the local reinforcement effect provided that a proper calibration is performed by installing a strain gauge, of the same type as that used on the structure, on a low modulus material. Experimental evidence of the proposed method is shown. Experimental proof of the positive effect of large grid lengths on the local reinforcement effect is also reported. © IMechE 2005.
2005
AJOVALASIT A, ZUCCARELLO B (2005). LOCAL REINFORCEMENT EFFECT OF A STRAIN GAUGE INSTALLATION ON LOW MODULUS MATERIALS. JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 40, 643-653 [10.1243/030932405X30894].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/30102
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 45
social impact