Starting from a 5 wt% ion power Nafion® solution and dissolving the dry residue in a suitable solvent (10 wt% solution in dimethylacetammide), re-cast Nafion films were developed for polymer electrolyte fuel cells (PEFCs) application. The used Doctor-Blade casting technique allowed to prepare scaled-up membranes comparable to the commercial Nafion ones with good mechanical resistance, thickness homogeneity and an excellent reproducibility. The differences between the re-cast membrane nanostructure and that of the commercial Nafion were investigated by synchrotron small-angle X-ray scattering. The obtained re-cast membrane shows at ambient conditions a semi-crystalline structure with a typical correlation length of about 86 °A and an intercluster Bragg distance of 37 A° , quite different from the values of commercial film. Observation on the swelling of the films revealed that the semi-crystalline structure, once soaked in water, swells less than the ionomeric part, leading to an unusual small-angle X-ray scattering (SAXS) profile in which the matrix and the ionomer peak are significantly overlapped. The ionic conductivity measured at T=80 ◦C shows slightly higher values for the re-cast Nafion membrane. A power density of about 0.490Wcm−2 at 0.6V and at T=80 ◦C in humidified hydrogen/air was obtained for the developed membrane.

SACCA' A, CARBONE A, PEDICINI R, PORTALE G, DILARIO L, LONGO A, et al. (2006). Structural and electrochemical investigation on re-cast Nafion membranes for polymer electrolyte fuel cells (PEFCs) application. JOURNAL OF MEMBRANE SCIENCE, 278(1-2), 105-113 [10.1016/j.memsci.2005.10.047].

Structural and electrochemical investigation on re-cast Nafion membranes for polymer electrolyte fuel cells (PEFCs) application

MARTORANA, Antonino;PASSALACQUA, Eva
2006-01-01

Abstract

Starting from a 5 wt% ion power Nafion® solution and dissolving the dry residue in a suitable solvent (10 wt% solution in dimethylacetammide), re-cast Nafion films were developed for polymer electrolyte fuel cells (PEFCs) application. The used Doctor-Blade casting technique allowed to prepare scaled-up membranes comparable to the commercial Nafion ones with good mechanical resistance, thickness homogeneity and an excellent reproducibility. The differences between the re-cast membrane nanostructure and that of the commercial Nafion were investigated by synchrotron small-angle X-ray scattering. The obtained re-cast membrane shows at ambient conditions a semi-crystalline structure with a typical correlation length of about 86 °A and an intercluster Bragg distance of 37 A° , quite different from the values of commercial film. Observation on the swelling of the films revealed that the semi-crystalline structure, once soaked in water, swells less than the ionomeric part, leading to an unusual small-angle X-ray scattering (SAXS) profile in which the matrix and the ionomer peak are significantly overlapped. The ionic conductivity measured at T=80 ◦C shows slightly higher values for the re-cast Nafion membrane. A power density of about 0.490Wcm−2 at 0.6V and at T=80 ◦C in humidified hydrogen/air was obtained for the developed membrane.
2006
SACCA' A, CARBONE A, PEDICINI R, PORTALE G, DILARIO L, LONGO A, et al. (2006). Structural and electrochemical investigation on re-cast Nafion membranes for polymer electrolyte fuel cells (PEFCs) application. JOURNAL OF MEMBRANE SCIENCE, 278(1-2), 105-113 [10.1016/j.memsci.2005.10.047].
File in questo prodotto:
File Dimensione Formato  
Martorana_Structural and electrochemical investigation.html

Solo gestori archvio

Dimensione 64.08 kB
Formato HTML
64.08 kB HTML   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/26095
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 56
social impact