Group A rotaviruses (RVAs) are the primary cause of acute gastroenteritis (AGE) in young children worldwide. Several commercial tests including latex agglutination, enzyme-linked assays (ELISA) and immunochromatographic tests (ICT) have been developed for the diagnosis of RVA infection. In the present study, the performance of two commercially available one-step chromatographic immunoassays, CerTest Rotavirus + Adenovirus (Biotec S.L, Zaragoza, Spain) and Vikia Rota-Adeno (bioMerieux SA, Lyon, France) were retrospectively evaluated using Real-time PCR as reference test. Re-testing by Real-time PCR of 2096 stool samples of children hospitalized with AGE previously screened by ICTs (1467 by CerTest and 629 by Vikia) allowed to calculate higher sensitivity for Vikia (94% vs 85% of CerTest) and higher specificity for CerTest (93% vs 89% of Vikia). Accordingly, higher Positive Predictive Values (87% vs 78%) and Positive Likelihood Ratios (12.32 vs 8.8) were found for CerTest and lower Negative Predictive Values (91% vs 97%) and Negative Likelihood Ratios (0.16 vs 0.06) for Vikia. However, both CerTest and Vikia showed a substantial agreement (κ = 0.79) with the Real-time PCR. A correlation between false negative results by ICTs and high Cycle Threshold values of Real-time PCR, indicative of low viral load, was observed. False positive results by the two ICT assays were not related to Norovirus, Adenovirus or Astrovirus infections, therefore the risk of cross-reactions was excluded. Both CerTest and VIKIA were able to detect the wide range of RVA genotypes circulating over the study period (including G1P[8], G2P[4], G3, G4, G9 and G12P[8]). The results of the present study showed a satisfactory efficacy of the two diagnostic tests analyzed.

De Grazia, S., Bonura, F., Pepe, A., Li Muli, S., Cappa, V., Collura, A., et al. (2017). Performance analysis of two immunochromatographic assays for the diagnosis of rotavirus infection. JOURNAL OF VIROLOGICAL METHODS, 243, 50-54 [10.1016/j.jviromet.2017.01.025].

Performance analysis of two immunochromatographic assays for the diagnosis of rotavirus infection

DE GRAZIA, Simona;BONURA, Floriana;URONE, Noemi;MATRANGA, Domenica;GIAMMANCO, Giovanni
2017-01-01

Abstract

Group A rotaviruses (RVAs) are the primary cause of acute gastroenteritis (AGE) in young children worldwide. Several commercial tests including latex agglutination, enzyme-linked assays (ELISA) and immunochromatographic tests (ICT) have been developed for the diagnosis of RVA infection. In the present study, the performance of two commercially available one-step chromatographic immunoassays, CerTest Rotavirus + Adenovirus (Biotec S.L, Zaragoza, Spain) and Vikia Rota-Adeno (bioMerieux SA, Lyon, France) were retrospectively evaluated using Real-time PCR as reference test. Re-testing by Real-time PCR of 2096 stool samples of children hospitalized with AGE previously screened by ICTs (1467 by CerTest and 629 by Vikia) allowed to calculate higher sensitivity for Vikia (94% vs 85% of CerTest) and higher specificity for CerTest (93% vs 89% of Vikia). Accordingly, higher Positive Predictive Values (87% vs 78%) and Positive Likelihood Ratios (12.32 vs 8.8) were found for CerTest and lower Negative Predictive Values (91% vs 97%) and Negative Likelihood Ratios (0.16 vs 0.06) for Vikia. However, both CerTest and Vikia showed a substantial agreement (κ = 0.79) with the Real-time PCR. A correlation between false negative results by ICTs and high Cycle Threshold values of Real-time PCR, indicative of low viral load, was observed. False positive results by the two ICT assays were not related to Norovirus, Adenovirus or Astrovirus infections, therefore the risk of cross-reactions was excluded. Both CerTest and VIKIA were able to detect the wide range of RVA genotypes circulating over the study period (including G1P[8], G2P[4], G3, G4, G9 and G12P[8]). The results of the present study showed a satisfactory efficacy of the two diagnostic tests analyzed.
2017
Settore MED/07 - Microbiologia E Microbiologia Clinica
De Grazia, S., Bonura, F., Pepe, A., Li Muli, S., Cappa, V., Collura, A., et al. (2017). Performance analysis of two immunochromatographic assays for the diagnosis of rotavirus infection. JOURNAL OF VIROLOGICAL METHODS, 243, 50-54 [10.1016/j.jviromet.2017.01.025].
File in questo prodotto:
File Dimensione Formato  
RotaICTsJVM17.pdf

Solo gestori archvio

Descrizione: Articolo principale
Dimensione 230.59 kB
Formato Adobe PDF
230.59 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/226410
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact