We aim at describing a non-parametric approach to evaluate blood cells velocity in oral capillascopic videos. The proposed methodology is based on the application of standard optical flow algorithms and it is part of a general environment to support during the diagnostic process for evaluating peripheral microcirculation in real time. We validated our approach versus handmade measurements provided by physicians. Results on real data pointed out that our system returns an output coherent to these latter observations

Adamo, A., Cacioppo, A., Messina, P., Scardina, G., Bellavia, F., Lupascu, C., et al. (2013). Flow evaluation of red blood cells in capillaroscopic videos. In Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems (pp. 477-480). Institute of Electrical and Electronics Engineers Inc. [10.1109/CBMS.2013.6627845].

Flow evaluation of red blood cells in capillaroscopic videos

CACIOPPO, Antonino;MESSINA, Pietro;SCARDINA, Giuseppe Alessandro;Bellavia, F.;TEGOLO, Domenico;VALENTI, Cesare Fabio
2013-01-01

Abstract

We aim at describing a non-parametric approach to evaluate blood cells velocity in oral capillascopic videos. The proposed methodology is based on the application of standard optical flow algorithms and it is part of a general environment to support during the diagnostic process for evaluating peripheral microcirculation in real time. We validated our approach versus handmade measurements provided by physicians. Results on real data pointed out that our system returns an output coherent to these latter observations
2013
Settore INF/01 - Informatica
978-1-4799-1053-3
Adamo, A., Cacioppo, A., Messina, P., Scardina, G., Bellavia, F., Lupascu, C., et al. (2013). Flow evaluation of red blood cells in capillaroscopic videos. In Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems (pp. 477-480). Institute of Electrical and Electronics Engineers Inc. [10.1109/CBMS.2013.6627845].
File in questo prodotto:
File Dimensione Formato  
Flow Evaluation of Red Blood Cells in Capillaroscopic Videos_.pdf

Solo gestori archvio

Dimensione 1.81 MB
Formato Adobe PDF
1.81 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/226202
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
social impact