Alongside with the development of Neutron Capture Therapy (NCT) and the use of thermal neutrons for radiotherapeutic purposes, many efforts have been devoted to the characterization of the beam in order to optimize therapy procedures. Reliable dose measurements should be able to determine the various (neutrons and photonic) components of the mixed beam usually employed for therapy. This paper studies the effect of additives such as boric and gadolinium nuclei on the sensitivity of neutron organic (alanine and ammonium tartrate) dosimeters analyzed through Electron Spin Resonance (ESR) technique (Marrale, 2014). These dosimeters were exposed to a mixed (neutron-gamma) field mainly composed of thermal neutrons. The choice of 10B and 64Gd as nuclei additives is due to their very high capture cross section for thermal neutrons. Also, after the nuclear reaction with thermal neutrons are emitted particles, which in turn release their energy in the vicinity of the reaction site (Marrale, 2008). The irradiation with mixed field (neutron-gamma) were performed within the thermal column of the TRIGA reactor, University of Pavia. Dosimeters readout was performed through the Electron Spin Resonance spectrometer Bruker ECS106 located at the Laboratory of Dosimetry ESR / TL of the Department of Physics and Chemistry - University of Palermo. We found that the addition of Gadolinium allows to largely increase the sensitivity of the dosimeters for thermal neutrons. In particular, a low concentration (5% by weight) of gadolinium oxide leads to an improvement of the sensitivity of neutrons more than 10 times. In addition, for this low content of gadolinium the photon tissue equivalence is not heavily reduced. This experimental analyses are compared with computational analyses carried out by means of Monte Carlo simulations performed with the MCNP (Monte Carlo N-Particle) transport code. A good agreement was observed for alanine dosimeters.

M. MARRALE, S. GALLO, A. LONGO, S. PANZECA, D. DONDI, E. TOMARCHIO, et al. (2016). Electron Spin Resonance dosimetry using organic compounds (alanine and ammonium tartrate) for mixed neutron-gamma fields. In Book of Abstract of Materials 2016 - Italian National Conference on Materials Science and Technology. Catania.

Electron Spin Resonance dosimetry using organic compounds (alanine and ammonium tartrate) for mixed neutron-gamma fields

MARRALE, Maurizio;GALLO, Salvatore;LONGO, Anna;PANZECA, Salvatore;TOMARCHIO, Elio Angelo;
2016-01-01

Abstract

Alongside with the development of Neutron Capture Therapy (NCT) and the use of thermal neutrons for radiotherapeutic purposes, many efforts have been devoted to the characterization of the beam in order to optimize therapy procedures. Reliable dose measurements should be able to determine the various (neutrons and photonic) components of the mixed beam usually employed for therapy. This paper studies the effect of additives such as boric and gadolinium nuclei on the sensitivity of neutron organic (alanine and ammonium tartrate) dosimeters analyzed through Electron Spin Resonance (ESR) technique (Marrale, 2014). These dosimeters were exposed to a mixed (neutron-gamma) field mainly composed of thermal neutrons. The choice of 10B and 64Gd as nuclei additives is due to their very high capture cross section for thermal neutrons. Also, after the nuclear reaction with thermal neutrons are emitted particles, which in turn release their energy in the vicinity of the reaction site (Marrale, 2008). The irradiation with mixed field (neutron-gamma) were performed within the thermal column of the TRIGA reactor, University of Pavia. Dosimeters readout was performed through the Electron Spin Resonance spectrometer Bruker ECS106 located at the Laboratory of Dosimetry ESR / TL of the Department of Physics and Chemistry - University of Palermo. We found that the addition of Gadolinium allows to largely increase the sensitivity of the dosimeters for thermal neutrons. In particular, a low concentration (5% by weight) of gadolinium oxide leads to an improvement of the sensitivity of neutrons more than 10 times. In addition, for this low content of gadolinium the photon tissue equivalence is not heavily reduced. This experimental analyses are compared with computational analyses carried out by means of Monte Carlo simulations performed with the MCNP (Monte Carlo N-Particle) transport code. A good agreement was observed for alanine dosimeters.
2016
ESR, EPR, Dosimetry
M. MARRALE, S. GALLO, A. LONGO, S. PANZECA, D. DONDI, E. TOMARCHIO, et al. (2016). Electron Spin Resonance dosimetry using organic compounds (alanine and ammonium tartrate) for mixed neutron-gamma fields. In Book of Abstract of Materials 2016 - Italian National Conference on Materials Science and Technology. Catania.
File in questo prodotto:
File Dimensione Formato  
CT2016_Poster_Tartrato_Neutroni.pdf

accesso aperto

Descrizione: Abstract
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/204622
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact