To evaluate the diagnostic accuracy of multislice computed tomography coronary angiography (MSCT-CA) in the detection of in-stent restenosis.Forty-two patients (33 male, 9 female, mean age 58+/-8 years) previously subjected to percutaneous implantation of coronary stent with suspected in-stent restenosis, underwent a 16-row MSCT (Sensation 16, Siemens) examination. The average time between stent implantation and MSCT-CA was 7.4+/-5.3 months. The following scan parameters were used: collimation 16x0.75 mm, rotation time 0.42 s, feed 3.0 mm/rot., kV 120, mAs 500. After administration of iodinated contrast material (Iomeprol 400 mgI/ml, 100 ml at 4 ml/s) and bolus chaser (40 ml of saline at 4 ml/s) the scan was completed in <20 s. All segments with a stent were assessed by two observers in consensus and were graded according to the following scheme: patent stent, in-stent intimal hyperplasia (IIH) (lumen reduction <50%), in-stent restenosis (ISR) (=/>50%), in-stent occlusion (ISO) (100%). Consensus reading was compared with coronary angiography.Forty-seven stents were assessed (16 in the right coronary artery; 4 in the left main; 22 in the left anterior descending; 5 in the circumflex). In 7 (17%) stents there was ISR (3) or ISO (4), and in 4 (10%) stents there was IIH. The sensitivity and negative predictive values for the detection of ISO were 80% and 98%, respectively, while for the detection of ISR+ISO they were 50% and 89%, respectively.Although the results are encouraging, the follow-up of stent patency with MSCT-CA does not show a diagnostic accuracy suitable for clinical implementation.

CADEMARTIRI F, MARANO R, RUNZA G, MOLLET N, NIEMAN K, LUCCICHENTI G, et al. (2005). Non invasive assessment of coronary artery stent patency with multislice CT : preliminary experience. LA RADIOLOGIA MEDICA, 109(5-6), 532-539.

Non invasive assessment of coronary artery stent patency with multislice CT : preliminary experience

RUNZA, Giuseppe;GALIA M;MIDIRI, Massimo
2005-01-01

Abstract

To evaluate the diagnostic accuracy of multislice computed tomography coronary angiography (MSCT-CA) in the detection of in-stent restenosis.Forty-two patients (33 male, 9 female, mean age 58+/-8 years) previously subjected to percutaneous implantation of coronary stent with suspected in-stent restenosis, underwent a 16-row MSCT (Sensation 16, Siemens) examination. The average time between stent implantation and MSCT-CA was 7.4+/-5.3 months. The following scan parameters were used: collimation 16x0.75 mm, rotation time 0.42 s, feed 3.0 mm/rot., kV 120, mAs 500. After administration of iodinated contrast material (Iomeprol 400 mgI/ml, 100 ml at 4 ml/s) and bolus chaser (40 ml of saline at 4 ml/s) the scan was completed in <20 s. All segments with a stent were assessed by two observers in consensus and were graded according to the following scheme: patent stent, in-stent intimal hyperplasia (IIH) (lumen reduction <50%), in-stent restenosis (ISR) (=/>50%), in-stent occlusion (ISO) (100%). Consensus reading was compared with coronary angiography.Forty-seven stents were assessed (16 in the right coronary artery; 4 in the left main; 22 in the left anterior descending; 5 in the circumflex). In 7 (17%) stents there was ISR (3) or ISO (4), and in 4 (10%) stents there was IIH. The sensitivity and negative predictive values for the detection of ISO were 80% and 98%, respectively, while for the detection of ISR+ISO they were 50% and 89%, respectively.Although the results are encouraging, the follow-up of stent patency with MSCT-CA does not show a diagnostic accuracy suitable for clinical implementation.
2005
CADEMARTIRI F, MARANO R, RUNZA G, MOLLET N, NIEMAN K, LUCCICHENTI G, et al. (2005). Non invasive assessment of coronary artery stent patency with multislice CT : preliminary experience. LA RADIOLOGIA MEDICA, 109(5-6), 532-539.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/17683
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 31
social impact