We simulated the electromechanical impedance (EMI) technique to assess the stability of dental implants. The technique consists of bonding a piezoelectric transducer to the element to be monitored. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer's electrical admittance. As the structural vibrations depend on the mechanical impedance of the element, the measurement of the transducer's admittance can be exploited to assess the element's health. In the study presented in this paper, we created a 3D finite element model to mimic a transducer bonded to the abutment of a dental implant placed in a host bone site. We simulated the healing that occurs after surgery by changing Young's modulus of the bone-implant interface. The results show that as Young's modulus of the interface increases, i.e. as the mechanical interlock of the implant within the bone is achieved, the electromechanical characteristic of the transducer changes. The model and the findings of this numerical study may be used in the future to predict and interpret experimental data, and to develop a robust and cost-effective method for the assessment of primary and secondary dental implant stability.

La Malfa Ribolla, E., Rizzo, P. (2015). Modeling the electromechanical impedance technique for the assessment of dental implant stability. JOURNAL OF BIOMECHANICS, 48(10), 1713-1720 [10.1016/j.jbiomech.2015.05.020].

Modeling the electromechanical impedance technique for the assessment of dental implant stability

La Malfa Ribolla, Emma;RIZZO, PIERVINCENZO
2015-01-01

Abstract

We simulated the electromechanical impedance (EMI) technique to assess the stability of dental implants. The technique consists of bonding a piezoelectric transducer to the element to be monitored. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer's electrical admittance. As the structural vibrations depend on the mechanical impedance of the element, the measurement of the transducer's admittance can be exploited to assess the element's health. In the study presented in this paper, we created a 3D finite element model to mimic a transducer bonded to the abutment of a dental implant placed in a host bone site. We simulated the healing that occurs after surgery by changing Young's modulus of the bone-implant interface. The results show that as Young's modulus of the interface increases, i.e. as the mechanical interlock of the implant within the bone is achieved, the electromechanical characteristic of the transducer changes. The model and the findings of this numerical study may be used in the future to predict and interpret experimental data, and to develop a robust and cost-effective method for the assessment of primary and secondary dental implant stability.
2015
La Malfa Ribolla, E., Rizzo, P. (2015). Modeling the electromechanical impedance technique for the assessment of dental implant stability. JOURNAL OF BIOMECHANICS, 48(10), 1713-1720 [10.1016/j.jbiomech.2015.05.020].
File in questo prodotto:
File Dimensione Formato  
2015_JOBIO.pdf

Solo gestori archvio

Dimensione 3.06 MB
Formato Adobe PDF
3.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/170610
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact