The ability to discriminate the quality of ionizing radiation is important because the biological effects produced in tissue strongly depends on both absorbed dose and linear energy transfer (LET) of ionizing particles. Here we present an experimental electron spin resonance (ESR) analysis aimed at discriminating the effective LETs of various radiation beams (e.g., 19.3 MeV protons, 60Co photons and thermal neutrons). The measurement of the intensities of the continuous wave spectrometer signal channel first harmonic in-phase and the second harmonic out-of-phase components are used to distinguish the radiation quality. A computational analysis, was carried out to evaluate the dependence of the first harmonic in-phase and second harmonic out-of-phase components on microwave power, modulation amplitude and relaxation times, and highlights that these components could be used to point out differences in the relaxation times. On the basis of this numerical analysis the experimental results are discussed. The methodology described in this study has the potential to provide information on radiation quality. © 2014 by Radiation Research Society.

Marrale, M., Longo, A., Brai, M., Barbon, A., Brustolon, M. (2014). Discrimination of radiation quality through second harmonic out-of-phase cw-ESR detection. RADIATION RESEARCH, 181(2), 184-192 [10.1667/RR13436.1].

Discrimination of radiation quality through second harmonic out-of-phase cw-ESR detection

MARRALE, Maurizio;LONGO, Anna;BRAI, Maria;
2014-01-01

Abstract

The ability to discriminate the quality of ionizing radiation is important because the biological effects produced in tissue strongly depends on both absorbed dose and linear energy transfer (LET) of ionizing particles. Here we present an experimental electron spin resonance (ESR) analysis aimed at discriminating the effective LETs of various radiation beams (e.g., 19.3 MeV protons, 60Co photons and thermal neutrons). The measurement of the intensities of the continuous wave spectrometer signal channel first harmonic in-phase and the second harmonic out-of-phase components are used to distinguish the radiation quality. A computational analysis, was carried out to evaluate the dependence of the first harmonic in-phase and second harmonic out-of-phase components on microwave power, modulation amplitude and relaxation times, and highlights that these components could be used to point out differences in the relaxation times. On the basis of this numerical analysis the experimental results are discussed. The methodology described in this study has the potential to provide information on radiation quality. © 2014 by Radiation Research Society.
2014
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
Marrale, M., Longo, A., Brai, M., Barbon, A., Brustolon, M. (2014). Discrimination of radiation quality through second harmonic out-of-phase cw-ESR detection. RADIATION RESEARCH, 181(2), 184-192 [10.1667/RR13436.1].
File in questo prodotto:
File Dimensione Formato  
2014_Article_RARE_second_harmonic.pdf

Solo gestori archvio

Dimensione 419.31 kB
Formato Adobe PDF
419.31 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/168553
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact