Multidetector computed tomography (MDCT) represents the main source of radiation exposure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT studies have been observed in the young trauma population with an increase in radiation exposure. We have identified 249 young adult patients (178 men and 71 women; age range 14–40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radiological Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software®. We have observed a mean cumulative dose of about 27 mSv (range from 3 to 297 mSv). The distribution analysis is characterised by low effective dose, below 20 mSv, in the majority of the patients. However, in 29 patients, the effective dose was found to be higher than 20 mSv. Dose distribution for the various organs analysed (breasts, ovaries, testicles, heart and eye lenses) shows an intense peak for lower doses, but in some cases high doses were recorded. Even though cumulative doses may have long-term effects, which are still under debate, high doses are observed in this specific group of young patients.

Salerno, S., Marrale, M., Geraci, C., Caruso, G., Lo Re, G., Lo Casto, A., et al. (2016). Cumulative doses analysis in young trauma patients: a single-centre experience. LA RADIOLOGIA MEDICA, 121(2), 144-152 [10.1007/s11547-015-0584-3].

Cumulative doses analysis in young trauma patients: a single-centre experience

SALERNO, Sergio
;
MARRALE, Maurizio;GERACI, Claudia;CARUSO, Giuseppe;Lo Re, G.;LO CASTO, Antonio;MIDIRI, Massimo
2016-01-01

Abstract

Multidetector computed tomography (MDCT) represents the main source of radiation exposure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT studies have been observed in the young trauma population with an increase in radiation exposure. We have identified 249 young adult patients (178 men and 71 women; age range 14–40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radiological Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software®. We have observed a mean cumulative dose of about 27 mSv (range from 3 to 297 mSv). The distribution analysis is characterised by low effective dose, below 20 mSv, in the majority of the patients. However, in 29 patients, the effective dose was found to be higher than 20 mSv. Dose distribution for the various organs analysed (breasts, ovaries, testicles, heart and eye lenses) shows an intense peak for lower doses, but in some cases high doses were recorded. Even though cumulative doses may have long-term effects, which are still under debate, high doses are observed in this specific group of young patients.
2016
Salerno, S., Marrale, M., Geraci, C., Caruso, G., Lo Re, G., Lo Casto, A., et al. (2016). Cumulative doses analysis in young trauma patients: a single-centre experience. LA RADIOLOGIA MEDICA, 121(2), 144-152 [10.1007/s11547-015-0584-3].
File in questo prodotto:
File Dimensione Formato  
Salerno2016_Article_CumulativeDosesAnalysisInYoung.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/158445
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact