In the harmonic active power measurement, the highest uncertainties are generally introduced by the current and voltage transducers. In a previous paper, the authors showed that the current transformer (CT) can introduce significant errors in such measurement, especially if the phase shift between voltage and current is close to ±90°. In such condition the errors on harmonic power measurement are mainly due to the CT phase displacement. This paper shows that better results can be achieved with more linear transducers, such as the Rogowski coil current transducers (RCCTs), whose metrological performance in distorted condition can be improved, by means of a proper compensation method. The proposed method for RCCTs compensation is based on the frequency response and it allows to reduce the errors on harmonic power measurement, also for phase shift close to ±90°. The study is supported by several experimental tests.

Cataliotti, A., Cosentino, V., Di Cara, D., Nuccio, S., Tinè, G. (2015). Rogowski coil current transducer compensation method for harmonic active power error. MEASUREMENT, 63, 240-251 [10.1016/j.measurement.2014.12.005].

Rogowski coil current transducer compensation method for harmonic active power error

CATALIOTTI, Antonio;COSENTINO, Valentina;NUCCIO, Salvatore;
2015-01-01

Abstract

In the harmonic active power measurement, the highest uncertainties are generally introduced by the current and voltage transducers. In a previous paper, the authors showed that the current transformer (CT) can introduce significant errors in such measurement, especially if the phase shift between voltage and current is close to ±90°. In such condition the errors on harmonic power measurement are mainly due to the CT phase displacement. This paper shows that better results can be achieved with more linear transducers, such as the Rogowski coil current transducers (RCCTs), whose metrological performance in distorted condition can be improved, by means of a proper compensation method. The proposed method for RCCTs compensation is based on the frequency response and it allows to reduce the errors on harmonic power measurement, also for phase shift close to ±90°. The study is supported by several experimental tests.
2015
Settore ING-INF/07 - Misure Elettriche E Elettroniche
Cataliotti, A., Cosentino, V., Di Cara, D., Nuccio, S., Tinè, G. (2015). Rogowski coil current transducer compensation method for harmonic active power error. MEASUREMENT, 63, 240-251 [10.1016/j.measurement.2014.12.005].
File in questo prodotto:
File Dimensione Formato  
MEASUREMENT_Rogowski coil current transducer compensation_.pdf

Solo gestori archvio

Descrizione: Articolo
Dimensione 1.66 MB
Formato Adobe PDF
1.66 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/149805
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 14
social impact