This study aimed to determine the feasibility, reproducibility, and reliability of the multiecho T*2 Magnetic resonance imaging technique at 3 T for myocardial and liver iron burden quantification and the relationship between T*2 values at 3 and 1.5 T. Thirty-eight transfusion-dependent patients and 20 healthy subjects were studied. Cardiac segmental and global T*2 values were calculated after developing a correction map to compensate the artifactual T*2 variations. The hepatic T*2 value was determined over a region of interest. The intraoperator and interoperator reproducibility for T*2 measurements at 3 T was good. A linear relationship was found between patients' R?*2 (1000/T*2) values at 3 and 1.5 T. Segmental correction factors were significantly higher at 3 T. A conversion formula returning T*2 values at 1.5 T from values at 3 T was proposed. A good diagnostic reliability for T*2 assessment at 3 T was demonstrated. Lower limits of normal for 3 T T*2 values were 23.3 ms, 21.1 ms, and 11.7 ms, for the global heart, mid-ventricular septum, and liver, respectively. In conclusion, T*2 quantification of iron burden in the mid-ventricular septum, global heart, and no heavymoderate livers resulted to be feasible, reproducible, and reliable at 3 T. Segmental heart T*2 analysis at 3 T may be challenging due to significantly higher susceptibility artifacts.

Meloni, A., Positano, V., Keilberg, P., De Marchi, D., Pepe, P., Zuccarelli, A., et al. (2012). Feasibility, reproducibility, and reliability for the T*2 iron evaluation at 3 T in comparison with 1.5 T. MAGNETIC RESONANCE IN MEDICINE, 68, 543-551 [10.1002/mrm.23236].

Feasibility, reproducibility, and reliability for the T*2 iron evaluation at 3 T in comparison with 1.5 T

MIDIRI, Massimo;
2012-01-01

Abstract

This study aimed to determine the feasibility, reproducibility, and reliability of the multiecho T*2 Magnetic resonance imaging technique at 3 T for myocardial and liver iron burden quantification and the relationship between T*2 values at 3 and 1.5 T. Thirty-eight transfusion-dependent patients and 20 healthy subjects were studied. Cardiac segmental and global T*2 values were calculated after developing a correction map to compensate the artifactual T*2 variations. The hepatic T*2 value was determined over a region of interest. The intraoperator and interoperator reproducibility for T*2 measurements at 3 T was good. A linear relationship was found between patients' R?*2 (1000/T*2) values at 3 and 1.5 T. Segmental correction factors were significantly higher at 3 T. A conversion formula returning T*2 values at 1.5 T from values at 3 T was proposed. A good diagnostic reliability for T*2 assessment at 3 T was demonstrated. Lower limits of normal for 3 T T*2 values were 23.3 ms, 21.1 ms, and 11.7 ms, for the global heart, mid-ventricular septum, and liver, respectively. In conclusion, T*2 quantification of iron burden in the mid-ventricular septum, global heart, and no heavymoderate livers resulted to be feasible, reproducible, and reliable at 3 T. Segmental heart T*2 analysis at 3 T may be challenging due to significantly higher susceptibility artifacts.
2012
Meloni, A., Positano, V., Keilberg, P., De Marchi, D., Pepe, P., Zuccarelli, A., et al. (2012). Feasibility, reproducibility, and reliability for the T*2 iron evaluation at 3 T in comparison with 1.5 T. MAGNETIC RESONANCE IN MEDICINE, 68, 543-551 [10.1002/mrm.23236].
File in questo prodotto:
File Dimensione Formato  
Feasibility, reproducibility, and reliability for the T2 iron evaluation at 3 T in comparison with 1.5 T.pdf

Solo gestori archvio

Dimensione 552.97 kB
Formato Adobe PDF
552.97 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/103297
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 47
social impact